Prepare Installation Space
Create the cut-out in the countertop according to the
installation diagram. The angle of the cut surface to the
countertop must be 90°.
The lateral cut-out edges must be flat in order to ensure
that the retaining springs are positioned properly on the
appliance. With multi-layered countertops, secure strips
laterally in the cut-out if necessary.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat- and water-resistant manner.
Observe minimum distance between device underside
and cabinet surfaces of
Cutout dimensions for 30" cooktops
Model: CIT30XWBB
6
/
" (10 mm).
3
8
P r e p a r e I n s t a l l a t i o n S p a c e
Cutout dimensions for 36" cooktops
Model: CIT36XWB, CIT36XWBB
Ventilation
To assure that the appliance works correctly, the cooktop
MUST be sufficiently ventilated.
Since the ventilation in the lower section of the appliance
requires a sufficient supply of fresh air, the cabinet must
be designed accordingly. The following is required for
this:
A minimum clearance between the rear of the cabinet
▯
and the kitchen wall, and between the surface of the
worktop and the upper area of the drawer.