Advanced Programming - V2 LEX-RFO40-230V Manual Del Usuario

Motorreductor tubular para persianas de lamas orientables
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35

ADVANCED PROGRAMMING

To perform ADVANCED programming it is necessary to activate
the programming by following one of the following procedures.
ACTIVATION OF PROGRAMMING
Artemis with 1 channel:
Press the STOP+UP+DOWN keys until the 6 LEDs light up
Release the keys: the programming remains active for 30
seconds during which the LEDs flash
Artemis with 2 channels:
Press the STOP+UP+DOWN keys of the channel to be
programmed until the LEDs light up
Release the keys: the programming remains active for 30
seconds during which the LEDs flash
Artemis with 6 channels:
Select the channel to be programmed with the C key
Press the STOP+UP+DOWN keys until the 6 LEDs light up
Release the keys: the programming remains active for 30
seconds during which the LEDs flash
Note: this procedure will be the same for the programming
of all functions and will not be repeated in the following
paragraphs
List of available functions:
1. Transmitter memorization
2. Deletion of all memorized transmitters
3. Programming of opening limit switch
4. Programming of closing limit switch (closed louver blades)
5. Programming of opening position of adjustable louver blades
TRANSMITTER MEMORIZATION
m
CAUTION: The data storage of the first transmitter
determines the direction of motion of the motor.
To store a transmitter on a virgin control untit proceed as
follows:
1. Supply power only to the control unit to be programmed
2. Activate the ARTEMIS programming
3. Press the UP or DOWN keys until the LED 2 lights up with solid
light and the others flash.
4. Press the UP+DOWN keys until the motor starts to move in
one direction
5. Release the keys, the motor stops
6. Press the UP or DOWN keys according to the direction in
which the roll-up shutter was moving before it stopped:
-
if the roll-up shutter was being raised press the UP key;
direction obtained: the UP key raises the roll-up shutter,
the DOWN key lowers the roll-up shutter
-
if the roll-up shutter was being lowered press the DOWN
key; direction obtained: the DOWN key lowers the roll-up
shutter, the UP key raises the roll-up shutter.
7. To exit the programming mode press the STOP key
8. Try to operate the roll-up shutter and verify that it works
according to the logic described above. If the logic is reversed
it is necessary to delete all the codes stored (see "DELETION
OF ALL MEMORIZED TRANSMITTERS") and repeat the steps
above.
To add other remote controls follow steps 6, 7, 8 of the
procedure "RAPID TRANSMITTER DATA STORAGE"
DELETION OF ALL MEMORIZED
TRANSMITTERS
To delete all codes stored with an Artemis proceed as
follows:
1. Supply power only to the control unit to be programmed
2. Activate the ARTEMIS programming
3. Press the UP or DOWN keys until the LED 3 lights up with solid
light and the others flash
4. Press and hold down the UP+DOWN keys until the motor
moves in both directions which confirms the correct deletion
of the codes.
5. Release the keys
6. To exit the programming mode press the STOP key
To delete all codes NOT stored with an Artemis proceed as
follows:
1. Cut the power to the motor on which to delete all the codes
2. Activate the ARTEMIS programming
3. Press the UP or DOWN keys until the LED 3 lights up with solid
light
4. Press and hold down the UP+DOWN keys
5. Power the motor and wait until the motor moves in both
directions wich confirms the correct deletions of the codes
6. To exit the programming mode press the STOP key
- 20 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lex-rfe50-230v

Tabla de contenido