2.4. Output Parameters
Seven sensing functions and 4 application functions can be selected. These values can be independently adjusted
and used as source for the Switching Output 1 or 2; in addition to those, an external input can be selected for
SO2. After selecting one of these sources, it is possible to configure the output of the sensor with a SCTL55 or
an IO-Link master, following the seven steps shown in the Switching Output setup below.
Once the sensor has been disconnected from the master, it will switch to the SIO mode and keep the last
configuration setting.
1
1. SSC1
S.P.1 (trimmer/IO-Link)
S.P.2
Hysteresis (man./auto)
Logic
Single point
Two point
Windows
2. SSC2
S.P.1
S.P.2
Hysteresis
Logic
Single point
Two point
Windows
3. Temperature
4. Dust 1
5. Dust 2
6. EXT-Input
10
Rev.00 - 06.2021 | MAN PD30CTP/R IO-Link EN | © 2021 | CARLO GAVAZZI Industr6
2
3
Auto
adjust
Selector
A
SSC1
One of
1 to 7
Selector
B
SSC2
One of
1 to 7
7. Aplication functions
Pattern
Speed &
or
Recognition
Length
4
5
Logic
Time
A
A - B
delay
B
AND, OR,
ON, OFF
XOR, S-R
One-shot
Logic
Time
A - B
delay
AND, OR,
ON, OFF
A
XOR, S-R
One-shot
B
Divider
Object & Gap
or
or
function
Monitoring
6
7
Output
Sensor
inverter
output
N.O., N.C.
NPN, PNP,
Push-Pull
Output
Sensor
inverter
output
N.O., N.C.
NPN, PNP,
Push-Pull
EXT-Input
8
SO1
SO2
EXT-
Input