TECHNICAL DATA
TYPE
Thermal power
Family
GAS
Pressure
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
AT - IT - DK - GR - SE
COUNTRY
GAS CATEGORY
The burner meets protection level of IP X0D (IP 40) as EN 60529.
The burner is approved for intermittent operation as per Directive EN 676.
EC marking in compliance with Gas Appliance Directive 90/396/EC; PIN 0063AP6680.
Burner with EC marking in compliance with EC Directives:
Electromagnetic Compatibility 2004/108/EC, Low Voltage 2006/95/EC and
Machines 2006/42/EC.
Gas train in compliance with EN 676.
1 – Air dampers
2 – Damper fixing screws
3 – Grommet
4 – Hood fixing screw
5 – Air pressure switch
6 – Motor
7 – Lockout light with
reset button
8 – Control box
9 – 6 pole socket for gas train
10 – Capacitor
11 – Air damper opening motor
NOTE
The grommet (3) and the hood fixing screw (4), supplied as accessories, should be assembled on
the same side as the gas train.
3302
551T1
11 35kW
8 12 kWh/m
2
Pci
Pci 24 34 kWh/m
3
2
min. 10 mbar – max. 35 mbar
3
min. 10 mbar – max. 50 mbar
Single phase, 230 V ± 10%
0.75 A run current - 2800 rpm - 294 rad/s
2 F
primary 230 V / 0.2 A
0.15 kW
DE
II 2H3B/P
II 2ELL3B/P
7
8
9
4
3
9,500 30,000kcal/h
–
7,000 10,340 kcal/m
3
–
– 21,000 29,300 kcal/m
3
~
50Hz
–
secondary 8 kV
ES - GB - IE
II 2H3P
Fig. 1
5
6
1
GB
ENGLISH
3
3
LU
NL
II 2E3B/P
II 2L3B/P
D7387
10
11
1
2
2