Technical Features - Ober LACS G Instrucciones De Uso

Tabla de contenido

Publicidad

TECHNICAL FEATURES

Table 1
Model
LACS600G
LACS400G
LACS200G
LACS120G
LACS80G
LACS600GR
LACS400GR
LACS200GR
LACS120GR
LACS80GR
Air inlet 1/8" GAS; Ø inside tube min. 8 mm.
* Noise emission levels determined by using ISO/CD 15744
The results have been achieved by using an air pressure of 6 bar while operating, with an air flow equal or higher to
the indicated consumption, no air valves at the entry have been applied but a standard silencer at the exit.
NOISE
The table of technical specifications indicates the noise level- where the noise level exceeds 85 dB (A) the noise power is
also indicated. Ear protectors must be worn where the noise level exceeds 85 dB (A) at the operator position. We
recommend that you also wear ear protectors below this noise level.
Noise risk and hearing damage are related to the intensity of the noise source and the length of exposure. Noise risk
must be assessed on a case by case basis taking into account these two factors. Measures should be taken against
hearing damage in accordance with current Health and Safety regulations.
MATERIALS
Ober pneumatic motors are made from steel, aluminium, cast iron, rubber and plastic components that do not contain
substances harmful to the environment or people. However the individual materials should be disposed of separately in
accordance with national waste recycling regulations.
6
Code
Speed
No-load
(rpm)
8604135
600
8604134
350
8604133
230
8604132
130
8604131
70
8604140.1
500
8604139.1
300
8604138.1
190
8604137.1
110
8604136.1
55
Torque
Power
max power
(Nm)
(W)
17
430
30
430
46
430
83
430
147
430
13.5
400
24
400
37
400
66
400
118
400
Air
Weight
Consump.
(Nl/min.)
(Kg)
600
2
600
2
600
2.15
600
2.15
600
2.15
560
2
560
2
560
2.15
560
2.15
560
2.15
GB
Noise *
Lp
(dB(A))
80.4
80.4
80.4
80.4
80.4
80.4
80.4
80.4
80.4
80.4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lacs gr

Tabla de contenido