Equipment Setup Options
Option # Option Name
220
Cool Stages/
Compressor
Stages
(#200=Conv./
#200=HP
(149.14 kW)
221
Heat Stages/
Aux/E Stages
(#200=Conv./
#200=HP
(149.14 kW)
Note: For a complete listing of the ISU setting options, please see the T5+
Smart Product data file at resideo.com

Electrical Ratings

Terminal
W Heating
W2 (Aux) Heating
E Emergency Heat
Y Compressor Stage 1
Y2 Compressor Stage 2
G Fan
O/B Changeover
L/A Input
Option Value (factory default in bold)
0, 1, 2
Note: Select how many Cool or Compressor stages of your equipment
the thermostat will control. Maximum of 2 Cool/Compressor Stages.
)
Heat Stages: 0, 1, 2
Aux/E stages: 0, 1
Note: Select how many Heat or Aux/E stages of your equipment the
thermostat will control. Maximum of 2 Heat Stages for conventional
)
systems. Maximum of 1 Aux/E stage for systems with more than 1
heating equipment type.
Voltage (50Hz/60Hz)
20 Vac - 30 Vac
20 Vac - 30 Vac
20 Vac - 30 Vac
20 Vac - 30 Vac
20 Vac - 30 Vac
20 Vac - 30 Vac
20 Vac - 30 Vac
20 Vac - 30 Vac
Running Current
21
0.02 A - 1.0 A
0.02 A - 1.0 A
0.02 A - 0.5 A
0.02 A - 1.0 A
0.02 A - 1.0 A
0.02 A - 0.5 A
0.02 A - 0.5 A
0.02 A - 0.5 A