Hayward AquaRite + Manual Del Usuario página 44

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 49
Auxiliary relays
1
OK
6
OK
Measures
1
OK
4
OK
9
OK
14
Page 20 of 23
2
+
-
1
Auxiliary relays.
2
A maximum of four additional auxiliary relays
6
(water features, fountains, garden lighting, etc.)
can be controlled. This menu displays and allows
you to configure the relays that remain available
on your equipment.
3
Manual mode (ON/OFF).
4
Automatic mode: Starts up according to the
time slots used to set the start and end times.
They can be configured with the following
frequencies: daily, every 2 days, every 3 days,
every 4 days, every 5 days, weekly, every 2
weeks, every 3 weeks, every 4 weeks.
2
OK
5
OK
10
OK
15
9
Redox probe calibration:
Recommended every two months
during the pool season.
10
Calibration with reference solution
465 mV. Follow the on-screen
instructions (fig. 11).
12
Manual calibration: Allows you to set
the probes to 1 point (without solution)
USE ONLY GENUINE REPLACEMENT PARTS
AquaRite +
3
+
-
3
1
Measures: Adjustment of set points
and measuring probes.
2
Set points for each measurement.
3
Setting the set points.
4
pH probe calibration: Recommended
once a month during the pool season.
6
11
12
OK
– recommended only for adjusting
small deviations in readings.
13
Without removing the probe from the
water, use the + / - keys to adjust
the reading to your reference value
(photometer or other measuring
instrument).
4
+
-
5
Timer mode: An operating time can be
programmed in minutes. Each time you press
the front panel key associated with the relay, it
will be activated for the programmed time. This
function is recommended for timing the operation
of spa blowers.
6
Relay name: It is possible to name the auxiliary
relays individually according to the associated
functions. On the keyboard, use the up/down
arrows to move the cursor vertically and the
+/- buttons to move the cursor horizontally. To
confirm, press OK.
5
Calibration using buffer solutions
(liquids models pH7 / pH10 / neutral).
Follow the on-screen instructions
(fig. 6).
7
Manual calibration: Allows you to set
the probes to 1 point (without buffer
solution) – recommended only for
adjusting small deviations in readings.
7
OK
13
8
Without removing the
probe from the water, use
the + / - keys to adjust the
reading to your reference
value (photometer or other
measuring instrument).
14
Temperature probe calibration:
Allows you to set the probes to 1
point.
15
Without removing the probe from the
water, use the + / - keys to adjust
the reading to your reference value
(thermometer). The same conditions
should apply for measurements.
5
8
Rev. E

Publicidad

Tabla de contenido
loading

Tabla de contenido