9. Slide the tank drawer out and place the LP tank in the drawer. Connect the regulator as
shown in Figure 9. Turn the black handle clockwise to tighten. Turn the handle
counterclockwise to remove. The hose must point down. Check that the valve is turned all the
way clockwise to the "OFF" position. Open the tank valve. Apply a solution of soapy water to
the tank-regulator connection and to the valve-hose connection to check for leaks. If soap
bubbles continue to form, the connection has a leak. If a leak is found, close the tank valve
and tighten all connections.
NEVER USE A FLAME TO CHECK FOR LEAKS.
Figure 9
10. Tighten the threaded knobs (G) found on the tank tray (Figure 10) so that the LP tank
cannot move from side to side. Do not remove the plastic cap from the end of the threaded
section.
Figure 10
9