Interchange SFNC4010 Manual Para El Operador página 14

Tabla de contenido

Publicidad

SFNC4010
14
OPERATING THE TOOL
TESTING THE TOOL
1
ƒ Disconnect air hose from the tool.
ƒ Remove all fasteners from the tool.
ƒ ALL SCREWS MUST BE TIGHTENED.
ƒ If any screws are loose, tighten them.
ƒ THE SAFETY/PUSH LEVER AND TRIGGER MUST
MOVE SMOOTHLY.
ƒ Adjust the air pressure to 70psi.
ƒ Connect the air hose.
ƒ Do not load any fasteners in the tool.
ƒ THE TOOL MUST NOT LEAK AIR.
ƒ Remove finger from the trigger and press the safety/
push lever against the wood.
ƒ THE TOOL MUST NOT OPERATE.
2
ƒ Separate the safety/push lever from the wood.
ƒ Next, point the tool in a safe position, pull the trigger and
then hold that position for 5 seconds or longer.
ƒ THE TOOL MUST NOT OPERATE.
ƒ Without touching the trigger, depress the safety/push
lever against the work piece.
1
ƒ Pull the trigger.
ƒ THE TOOL MUST OPERATE IF SET IN SEQUENTIAL
FIRE MODE.
ƒ Hold the trigger back while separating the safety/push
lever from the wood.
2
ƒ Remove finger from the trigger.
ƒ TOOL OPERATION WILL END.
ƒ ﹙the driver blade will return to the top﹚.
ƒ With the tool off the work piece, pull the trigger.
ƒ Depress the safety/push lever against the work piece.
ƒ THE TOOL MUST OPERATE IF SET IN BUMP FIRE
MODE.
Interchange Brands Staplers: Operator's Manual

Publicidad

Tabla de contenido
loading

Productos relacionados para Interchange SFNC4010

Tabla de contenido