KYRA D 30 UNIT COND

5.4 Technical data table

Model
Max. heating capacity
Min. heating capacity
Max. heat output in heating (80/60)
Min. heat output in heating (80/60)
Max. heat output in heating (50/30)
Min. heat output in heating (50/30)
Effi ciency Pmax (80-60°C)
Effi ciency Pmin (80-60°C)
Effi ciency Pmax (50-30°C)
Effi ciency Pmin (50-30°C)
Effi ciency 30%
Effi ciency class according to directive 92/42 CE
Max. working pressure in heating
Min. working pressure in heating
Max. heating temperature
Heating water content
Heating expansion tank capacity
Heating expansion tank prefi lling pressure
Protection rating
Power supply voltage
Electrical power input
Empty weight
Combustion chamber length
Combustion chamber diameter
Pressure losses, fume side
A73022680
KYRA D 30 UNIT COND
kW
29,3
kW
16,0
kW
28,5
kW
15,6
kW
30,0
kW
16,6
%
97,0
%
97,6
%
102,3
%
105,5
%
103,7

bar
3
bar
0,8
°C
80
liters
49
liters
10
bar
1
IP
X0D
V/Hz
230/50
W
190
kg
115
mm
280
mm
220
mbar
0,35
(Q)
(Q)
(P)
(P)
(P)
(P)
(PMS)
(tmáx)
EN
41