TECHNICAL DATA SHEET
Working air pressure
Working temperature
Air consumption
Compatible oils
Pneumatic system pipes
Aerial Noise
Acoustic radiation pressure measured: 60 dBA
Tests carried out in conformity with the standards ISO/R 1680 - 1970. Instrument: LARSON DAVIS 800 B PRECISION ANALYSER
PHONOMETER in conformity with the standards IEC 804 E 651 class 1 set with a Larson Davis Ca 250 114/b 250 Hz calibrator
before and at the end of the measurements.
Measurements and dimensions - YAK 217/N
18
8 > 10 bar
116 > 145 psi
-20°C > +50°C
-4°F > 122°F
400 nl/min
ATF Dexron IID
Rilsan ø 6x4 mm
Weight
Max. stroke
1st stage capacity
2nd stage capacity
3rd stage capacity
4th stage capacity
5th stage capacity
41 Kg
90 lb
171 mm
6.7 in
40 t
44 ton (short)
20 t
22 ton (short)
-
-
-
525 mm
A
20.7 in
270 mm
B
10.6 in
170 mm
C
6.7 in
171 mm
D
6.7 in
88 mm
E
3.5 in
83 mm
F
3.3 in
300 mm
G
11.8 in
206 mm
H
8.1 in
1320 mm
I
52 in
1400 mm
L
55.1 in
EN