Interruption of Work till 4 Hours
T urn the machine off.
W hen processing 2-component varnishes, clean the device immediately.
Taking Out of Operation and Cleaning
Proper cleaning is the prerequisite for problem-free operation of the paint application
device. No warranty claims are accepted in case of improper or no cleaning.
1) Unplug the power plug. Vent the container in case of longer breaks and after the work
has been terminated. This can be done by briefly turning open and then closing the container
or by pulling the trigger guard and letting the paint into the original paint container.
2) Divide the spray gun. Press the hook (Fig. 3 b "click") slightly downwards. Turn the gun front
part and gun rear part against each other.
3) Unscrew the container. Empty any remaining coating material back into the material tin.
4) Preclean the container and suction tube with a brush. Clean the ventilating bore
(Fig. 10, C).
5) Pour solvent or water into the container. Screw the container back on. Do not use flammable
materials for cleaning purposes.
6) Assemble the gun again (Fig. 3).
7) Insert the power plug, turn on the machine and spray the solvent or water into a container
or a cloth.
8) Repeat the above procedure until the solvent or water emerging from the nozzle is clear.
9) Turn off the machine and remove the plug.
10) Screw of the container and empty it. Pull out the suction tube with container seal.
CAUTION! Never clean seals, diaphragm and nozzle or air holes of the spray gun with
metal objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
11) Pull the ventilating hose (Fig. 10 A, 13) at the top from the gun body. Screw off the valve
cover (14). Remove the diaphragm (15). Clean all the parts carefully.
WARNING!
12) Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
13) Unscrew the union nut and remove the air cap and nozzle. Clean the air cap and nozzle
with a brush and solvent or water.
Assembly
The unit may only be operated with an integer diaphragm (Fig. 10 A, 15). Place the diaphragm
with the pin facing upwards on the bottom section of the valve. Also see the marking on the
gun body. Place on the valve cover and screw it closed. Place the ventilating hose on the valve
cover and on the nipple at the gun body.
Attention! Never operate the device if the nozzle seal is either damaged or
missing. If the nozzle seal is either missing or damaged liquids can enter
the device and increase the risk of an electric shock.
Slide the nozzle seal (Item 4) with the groove (slot) facing forwards into the nozzle
Never hold the spray gun rear part under water or immerse
it into liquids. Clean the housing only with a moistened
cloth.