Installation Instructions - Gabarron SH6M Instrucciones De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INTRODUCTION
Storage heaters are designed to take advantage of the considerable economical benefits of any restricted hour electricity tariff.
The heaters consume electricity only during the off-peak tariff, but due to the highly efficient storage medium, give you a truly
economical 24 hours of comfort temperatures. Supply with 220-240V~.
Type
Input
Voltage
Charge
Weight
L
W
H
7,5 kg brick
11,5 kg brick
The input control operates a highly sensitive thermostat which regulates the amount of heat stored.
The discharge is by convection heat which can be partially controlled by use of the output control. Please note that type
SH6M is fully automatic with no output control.
It is important that the correct rating of heater is installed to provide the selected level of heat. This will ensure the best
possible running costs against other fuels.
To reduce transport problems, the heater casings and storage bricks are packed separately. You should be aware that Storage
heaters, when fully charged, can have high surface temperatures.

2. INSTALLATION INSTRUCTIONS

1.- Chose the right place to install the heater. It is necessary that a minimum clearance of 50 cm is allowed to ensure the best
heating results. Always maintain a minimum clearance of 50 cm from the heater to any combustible materials such as furniture
and curtains.
2.- Open the carton at the indicated side and fix the feet without removing the heater casing (fig 1). The screws are in the
accessories bag. Turn the carton upside down to allow the heater to stand on its feet and remove the carton. Check that it is
the correct model and that it is in good condition.
3.- Take off the front panel by removing the two screws at the bottom of the heater.
4.- Set the heater in the selected installation area and mark the fixing points on the wall using a pencil. Use the heater fixing
holes as a template and mark the wall through the fixing holes. Drill the required holes into the wall.
SH6M
SH9M / A
0.8 kW
1.2 kW
6.4 kWh
9.6 kWh
39 kg
56 kg
31.5 cm
43 cm
4
-
-
4
fig 1
SH12M / A
SH15M / A
1.6 kW
2.0 kW
220 – 240 V~
12.8 kWh
16.0 kWh
73 kg
90 kg
54 cm
65 cm
15 cm
72.5 cm
8
4
-
4
7
SH18M / A
SH24M / A
2.4 kW
3.2 kW
19.2 kWh
25.6 kWh
108 kg
142 kg
76.5 cm
99 cm
12
-
fig 2
16
-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sh9mSh9aSh12mSh12aSh15mSh15a ... Mostrar todo

Tabla de contenido