EN
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install
a properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any
hose coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 16576175 and table on page 2. Maintenance frequencies are shown in
circular arrows and are defined as h=hours, d=days, and m=months. Items identified as:
1. Air filter
2. Regulator
3. Lubricator
4. Emergency shut-off valve
5. Hose diameter
Note: Before storing the tool or leaving idle exceeding 24 hours:
- Pour 3 cm
of IR # 10 oil into air inlet and run tool for 5 seconds.
3
Note: If the action of the tool becomes sluggish:
- Pour 3 cm
of cleaning solution into air inlet and run tool for 30 seconds.
3
- Immediately after flushing the tool, pour 3 cm
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled, de-
greased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
EN-2
6.
Thread size
7.
Coupling
8.
Safety Air Fuse
9.
Oil
10. Oil - before starting, into air inlet
of oil into air inlet and run tool for 30 seconds.
3
03525763_ed11