GB
IRL
Preparation
Observe the instructions in the chapter entitled „Safety".
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
1. Pull up the red button on the safety valve [10] until all excess pressure is released from
the tank. (Fig. 4)
2. Press the pump handle [11] down and turn it counterclockwise.
► The pump handle is locked in place. (Fig. 5)
3. Unscrew the pump [4] from the tank [2]. (Fig. 6)
+
We recommend you mix the spraying liquid in the device or premix it in an external
tank: Fill to 1/3 with water, pour in the spraying agent, and then add more water until
full.
4. Add the spraying liquid to the tank [2]. (Fig. 7)
5. Screw the pump [4] onto the tank [2]. (Fig. 9)
6. Press the pump handle [11] down and turn it clockwise.
► The pump handle is unlocked. (Fig. 10)
7. Generate the desired pressure (→ Table 2, next page) in the tank [2] (Fig. 11).
+
The maximum pressure should not exceed 6 bar (red line on the pressure gage [14],
Fig. 11). If the maximum pressure is exceeded, the safety valve will engage and
release the excess pressure.
8. Press the pump handle [11] down and turn it counterclockwise.
► The pump handle is locked in place. (Fig. 5)
AUS
USA
16
NZ
CDN
IND