Audible Alarm (not shown)
getting low and the inverter is about to shut down. If you can reduce the AC load,
you can temporarily extend operating time. Charge the battery as soon as possible.
REAR PANEL
All inverters described in this manual have two terminals for connecting battery
cables. One terminal is the Positive (+) terminal [red]; the other is the Negative (−)
terminal [black]. The Positive battery cable should have a Battery Protection Fuse
installed within one foot of the battery connection. The negative cable can be
directly attached to the negative battery terminal. In some cases, a metal vehicle
frame can be used as part of the negative cable to the battery.
High Speed Fan – The fans turn on when there is a high load or an elevated
temperature to keep the inverter cool. Do not block. Keep 2-inch clearance.
Ground Terminal – This terminal is for attaching a 6 gauge insulated safety ground
wire. This safety wire protects personnel if there is an unlikely failure in either the
cabling or enclosure insulation. Do not directly connect this ground to the negative
DC terminal on the inverter. This safety wire is to be connected to the vehicle
frame or earth ground or negative battery terminal as described in the installation
procedure.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
User's Manual—Read before using this equipment
–
when it sounds, it indicates that the battery voltage is
©2016 Wagan Corporation. All Rights Reserved.
Negative Terminal (black)
Positive Terminal (red)
Cooling Fans (internal)
Ground Terminal
Vent Grills
4