Operating Instructions
OPERATING INSTRUCTIONS
(Continued)
UNLOADING THE NAILER
1. Always unload all fasteners before
removing tool from service.
Unloading is the reverse of loading,
except always disconnect the air
hose before unloading.
2. Pull nail pusher
mechanism back and
press "Nail Bypass
Button."
3. Hold tool upright so
nails will slide out of
magazine.
4. Release the Pusher.

ADJUSTING THE NAIL PENETRATION

The IFN35650 is equipped with an
adjustable depth of drive feature. This
allows the user to determine how deep
a fastener will be driven into the work
surface.
1. Adjust the
operating
pressure to a
COUNTER-
CLOCKWISE
pressure which
will consistently
drive the
fasteners. Do not exceed the
maximum operating pressure of the
nailer of 110 psi.
2. To increase
depth of drive,
first pull up on
the upper WCE,
then rotate
thumbwheel
to the left (counter-clockwise). To
decrease depth of drive, rotate
thumbwheel to the right (clockwise).
Then release upper WCE into
detents which hold the thumbwheel
in place after each adjustment.
3. Make sure that the
trigger and work
contact element
(WCE) move freely
up and down without binding or
sticking after each adjustment.
www.chpower.com
ADJUSTING THE DIRECTION OF THE
EXHAUST
The IFN35650 is
equipped with an
adjustable direction
exhaust deflector.
This is intended to allow the user to
change the direction of the exhaust.
Simply twist the deflector to any
direction desired.
Nail
Pusher
Mechanism

CLEARING A JAM FROM THE TOOL

Nail Bypass Button
1. Disconnect the air
supply from the tool.
2. Remove all nails from
the magazine (see
"Loading/ Unloading
The Nailer"). Failure
to do so will cause the nails to eject
from the front of the nailer.
3. Undo latch by pulling
out and down.
The wire latch will
disengage from the
hooks on the nose.
4. The door can now be
rotated, exposing the
jammed fastener.
CLOCKWISE
5. Remove the jammed
fastener, using pliers
or a screwdriver if
required.
6. Rotate door back into
the closed position.
7. Extend the wire latch
and place over the
hooks on the nose.
8. Close the latch by
pushing the latch up
and in until the latch
snaps into place.
9. Make sure the trigger
and work contact
element (WCE) move
Movement
Movement
freely up and down
without sticking or binding.
USER-MAINTENANCE
INSTRUCTIONS
TECHNICAL SERVICE
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
Rotate
Rotate
the operation or repair of this tool or
for additional copies of this manual.
FASTENER AND REPLACEMENT
PARTS
Use only genuine Campbell Hausfeld
replacement parts. Never substitute
parts. Do not use modifi ed parts or
parts which will not give equivalent
performance to the original equipment.
Tool performance, safety and durability
could be reduced. When ordering
replacement parts or fasteners, specify
by part number.
TOOL REPAIR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. After
reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.
STORAGE
The stapler should be stored in a cool
dry place.
Movement
Movement
6
Use only 15 gauge
35° fasteners.

Publicidad

Tabla de contenido
loading