Configurations:
Dip switch N°6 sets the low-battery protection thereshold at 12.0V with SW6 set ON and at 12.5V with SW6
OFF. It exits from a low battery protection only during daylight when battery voltage is upper 13.2V. When is
active low battery protection led is red flashing.
Switchs
Description
1
Standard battery charger*:
ON
Loads A and B always on.
Complete "light sensor" with complementary outputs*:
1
ON
Load A ON only during day.
Load B ON only during night.
1
Remote load *:
ON
The load is controlled by the contact on Sens input; closed to gnd => load A ON, opened => load A
OFF. Load B always ON.
1
Light sensor with IR *:
Load A ON during night ("light sensor" by the panel) for 5 minutes every time the IR sensor notices
ON
the passage of a person.
Load B ON only during night.
Lamp ON for all night long*:
1
ON
Load activated during night, from sunset (detected by the PV module) until sunset.
LOAD B manages the lamp energy saving
LoadA
LoadB
Lamp to max Brightness
Lamp in energy save, half brightness
Lamp off
1
Light sensor with timer 6h *:
ON
Load ON during night, from sunset (revealed by the module) for 6 hours.
Load B manages the lamp energy saving (see * temporal diagram)
1
Light sensor with timer 8h *:
ON
Load ON during night, from sunset (revealed by the module) for 8 hours.
Load B manages the lamp energy saving (see * temporal diagram)
1
Light sensor with timer 8h delay 1h *8
ON
Load ON during night, one hour after sunset (revealed by the module) for 3 hours.
Load B manages the lamp energy saving (see * temporal diagram)
1
Light sensor with timer 10h *:
ON
Load ON during night, from sunset (revealed by the module) for 10 hours.
Load B manages the lamp energy saving (see * temporal diagram)
*(see temporal diagram)
LoadA
LoadB
Lamp to max Brightness
Lamp in energy save, half brightness
Lamp off
1
Road flashing indicator - alternated 50% *:
Lightning loads at 50% (0,5s A on and B off, 0,5s A off and B on). From twilight ("light sensor" by the
ON
panel) and for the whole period of darkness, the power supplied to loads is reduced to a half.
1
Road flashing indicator - alternated flash *:
Alternating lighting loads with a flash of 20ms for each second. From twilight ("light sensor" by the
ON
panel) and for the whole period of darkness, the power supplied to loads is reduced.
WARNING: The configurations in the table are valid for controllers with software versions 2.12 (see image in the previous page
*
to understand the version of your SPC07-IP LiFePO4).
timer
2 min
2 min
timer
2 min
2 min
SPC07-IP LiFePO4
User manual
3
Scheme of load connection
BLU
VERDE/GREEN
IR Sensor
PX01
ROSSO/RED
DIMMER
GND
12V
You can exclude the Energy saving not connecting the dimmer
signal. In this way the lamp will remain ON for all the time of
the timer at its maximum luminosity.
Semaforo/
Semaphore
+LoadA
-LoadA
+LoadB
-LoadB
SPC07-IP
EN
Gnd
Sens
+LoadA
-LoadA
12V Aux Max 100mA
+LoadB
-LoadB