Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
• Max. flow:
0.8 L/cycle or 0.2 gpc / 0.41 MPa (60 psi)
• Flow pressure:
- min.
- recommended
0.1 - 0.5 MPa (14.5 - 72.5 psi)
• Operating pressure:
• Test pressure:
• Hot water supply temperature:
Recommended (energy economy):
Thermal disinfection possible.
Fitting with battery:
• Voltage supply:
6V lithium battery type CR-P2
Fitting with switched-mode power supply (42 464):
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
• Automatic safety shut-off
(6 - 420 s adjustable):
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (adjustable):
• Type of fitting protection:
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in connection hose dirty
1
English
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa (72.5 psi), a pressure-
reducing valve must be installed.
Major pressure differences between cold and hot water supply
should be avoided.
Installation
Flush piping system prior and after installation of
fitting thoroughly!
Open cold and hot water supply and check
connections for leakage.
Setting temperature limiter,
0.05 MPa (7.25 psi)
see fold-out page II.
max. 1 MPa (145 psi)
1.6 MPa (232 psi)
Operation,
max. 158 °F
see technical product information, 99.0438.xxx.
140 °F
Maintenance
• Shut off hot and cold water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if
2.4 W
Replacement parts
see fold-out page I (* = special accessories)
11 s
1 s
,
Care
approx. 5"
Instructions for care of this faucet will be found in the Limited
IP 59K
Warranty supplement.
, see fold-out page I.
, see fold-out page II.
necessary.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
A
2
2500 V
100 °C