DUSI01EN - v6
6 TROUBLESHOOTING
OPTIMA selector
If the monitoring programme detects a
problem in door operation, a numerical code
will flash the display.
In most cases, to restore door operation simply select the door OPEN mode and then the door AUTOMATIC mode. If the prob-
lem persists, contact an manusa authorised Technical Service.
MALFUNCTION
POSSIBLE CAUSE
a. Mains overcurrent
OVERCURRENT
b. Short circuit in motor or
0001
circuit.
Overcurrent in motor
a. Panic break-out leaves
SOS
open.
0002
b.
Emergency signal activated
Obstruction
OBST CLOSING
closing cycle.
0003
Obstruction on closing
The outside key switch has
OUTSIDE KEY SWITCH
not been removed from the
0004
device.
Outside key switch activated
Parameter
DOOR PARAM MEM.
falling.
0005
Parameters memory
Obstruction
OBST. OPENING
opening cycle.
0006
Obstruction on opening
The IR barriers are blocked
PHOTOCELL
for a period > 1'.
0008
IR barriers
Fire alarm signal activated.
FIRE ALARM
0009
Infrared barriers
a. Low battery.
LOW BATTERY
b. Low mains voltage.
0011
Panic door system
NOTE: The features included in this document are given for
information purposes only, and are not binding.
Last updated: May 2010
SOLUTION
Change to OPEN followed
by AUTOMATIC mode to
resume normal operation. If
the problem persists, call
the Technical Service.
a.
b.
within
the
to OPEN
followed by AUTOMATIC
mode
memory
is
Call Technical Service.
within
the
to OPEN
followed by AUTOMATIC
mode
Check the alignment of the
IR barriers.
Check fire alarm system.
If
the
door
was
disconnected,
leave
the
door connected during 24
hours
to
charge
the
batteries. If the warning
persists, call the Technical
Service.
SMART selector
If
the
problems in the door operation, a numerical
code flashes in the display along with an
icon indicating the problem.
MALFUNCTION
POSSIBLE CAUSE
Radar contact permanently
INSIDE RADAR
closed for a period of > 1'.
0012
Malfunction in internal radar
Radar contact permanently
OUTSIDE RADAR
closed for a period of > 1'.
0013
Malfunction in external radar
The
PHOTOCELL 3
blocked.
0014
IR Barrier 3
Malfunction in the control
MOTOR CONTROL
board.
0015
Safety
SAFETY SENSOR
activated.
0016
Malfunction on side sensors
The LCD screen
The selector has no power.
does not light up
No communication with the
LOADING DATA
operator.
----
Communication fault occurs
when the following message
appears on screen:
"loading data"
HEAD OFFICE
Av. Vía Augusta, 85-87, 6th
08174 Sant Cugat del Vallés
Barcelona - Spain
Tel. +34 902 321 400
Fax +34 902 321 450
24
monitoring
programme
detects
SOLUTION
Call Technical Service.
Call Technical Service.
third
IR
barrier
is
Call Technical Service.
Change to OPEN followed
by AUTOMATIC mode to
resume normal operation. If
the problem persists, call
the Technical Service.
opening
signal
Verify that there is no object
within the sensor detection
area.
Check door power supply.
Call Technical Service.
FACTORY
Ctra. Pla de Sta. María 235-239
43800 Valls - Tarragona (Spain)
Tel. +34 902 321 700
Fax +34 902 321 750
www.manusa.com

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para Manusa Visio Serie

Este manual también es adecuado para:

Visio ldVisio mdVisio hd

Tabla de contenido