Cleaning, Measures after use, Dismantling / DIsposal
Cleaning after each operation
Clean the pump by flushing an appropriate cleaning agent.
First pump the cleaning agent in circuit, then rinse with
clean detergent.
Do not remove motor from the pump as long as there is
any back pressure.
Before removing the motor from the pump, completely
drain pump, flexible hose and fittings.
Do not use flammable liquids to clean the pump.
The pump and hose must be compatible with
the cleaning agent.
The pump should not be immersed deeper into
the cleaning agent than the outlet connection.
Dismantling of pump for cleaning :
1. Remove the plug.
2. Release union nut between motor and pump.
3. Remove the motor.
4. Remove inner tube from the pump.
Measures after use
Attention!
Empty pump, hose and fittings after every use.
Drain hand nozzle after use. Otherwise liquid being
contained within the outlet tube will flow out without control.
Dismantling and Disposal
Pump, hose and fittings must be emptied prior to dismantling.
Prior to dismantling the outlet tube switch the pump off and
disconnect the mains.
Collect environmentally harmful substances and liquids in
appropriate containers and dispose of them in an environmen-
tally sound manner.
Dispose of scrap material and parts that cannot be repaired or
reused in an environmentally sound manner.
Testing / Repair
Testing / Repair
Regulary check the pump according to the relevant national
safety instruction and/or rules for prevention of accidents
(in Germany these are e.g. BGV A3).
Repairs should only be carried out by the manufacturer
or an authorized repair shop.
Note
Depressurise the system.
Separate pump from current.
Empty hose and hand nozzle.
Always replace defective parts.
Only use genuine spare parts.
There must be at least 6 balls in the swivel joint.
Replacement of hose connector and / or seal:
1. Take off the safety lever (screw out safety screw)
2. Take out the balls off the swivel joint (maybe with the help of a
magnet pin)
18
19
Ball
Seal
Hose connector
Safety screw
Safety lever