IT
►2.16.In any condition of use or appliance
GB
standstill, make sure that the fl exible gas
hose is not damaged (crushed, bent,
DE
twisted, taught).
ES
►2.17.If the smell of gas is perceived,
switch the appliance off immediately,
FR
close the gas cylinder, disconnect the
mains plug and then contact the after-
NL
sales assistance.
PT
►2.18.If the gas hose must be replaced,
only use the fl exible type suitable for
DK
the pressure used, referring to national
FI
regulations. The gas hose must measure
1,5 m.
NO
►2.19.When the appliance is controlled
by a room thermostat (optional article),
SE
the generator can switch back on at any
PL
time i.e. when the temperature drops
below the threshold set.
RU
►2.20.When it is not used, disconnect
the generator from the network plug,
CZ
close the gas supply, disconnect the gas
HU
hose from the generator and plug the gas
inlet on the generator.
SI
►2.21.Have the after-sales assistance
check correct functioning of the generator
TR
at least once a year and/or according to
HR
need.
LT
►►3. TYPE OF FUEL
LV
Use category I
3
EE
►►4. CONNECTION AND
REPLACEMENT OF THE GAS
RO
CYLINDER
SK
The gas cylinder must be replaced in the
open air, away from heat sources, in an
BG
atmosphere without fl ames.
Only the following accessories must be
GR
used for connection of the gas cylinder to
CN
the generator:
•Liquid gas fl exible pipe.
•Liquid gas pressure regulator complete
with safety valve.
B/P gas only.
CHECK THE INTEGRITY OF THE GAS
SUPPLY PIPE. IF THE GAS HOSE
MUST BE REPLACED, ONLY USE THE
FLEXIBLE TYPE SUITABLE FOR THE
PRESSURE USED, REFERRING TO
NATIONAL REGULATIONS.
►To connect the generator to the gas
cylinder:
ATTENTION:
ALL
SINISTRAL, I.E. THEY ARE TIGHTENED
IN AN ANTI-CLOCKWISE DIRECTION.
►4.1.Screw the gas hose to the generator
fi tting (Fig. 4).
►4.2.Install the pressure regulator on the
gas cylinder. Make sure there is a gasket
present on the regulator (if envisioned by
the type of connection) (Fig. 5).
►4.3.Connect the gas hose to the
pressure regulator (Fig. 6).
►4.4.Open the gas cylinder cock (Fig.
7).
►4.5.Press
the
button (Fig. 8). Check tightness of
fi ttings using soapy water: bubbles
indicate a gas leak (Fig. 9). Several
gas cylinders can be fi tted together to
obtain greater autonomy. The use of
30 kg gas cylinders is recommended,
up to heating capacity of 33 kW. Over
the power of 33 kW use gas cylinders
with greater capacity. The use of gas
cylinders with suitable capacity is
recommended in order to prevent
problems due to lack of gasifi cation of
the fuel. The correct functioning pressure
(see data plate applied to the generator)
is given by the regulator supplied or an
equivalent model.
THREADING
IS
regulator
release