Air Inlet
A. The compressor should never be used without an inlet
filter. A dirty or restricted filter will affect performance and
cause the compressor to pass an excessive amount of oil.
The maximum inlet restriction with the compressor running
at 2400 rpm and pumping to atmosphere is 20 inches of
water. If intake vacuum exceeds 20 inches of water , the
intake filter must be changed. Haldex compressors in the
EL or EL(X) series may be supercharged up to 35 psi inlet
air pressure. Warranty is given in supercharged service for
all compressors in the EL or EL(X) series.
Escape
Air
20" H
O Max.
2
2400 RPM
Filter Incoming Air To 40 Microns
Maximum
A. Clean air is necessary to prevent excessive cylinder and
ring wear. It is also necessary for operation of brake
valves operating under close clearances.
Drive System
A. The compressor installation and drive system has an influ-
ence on compressor life. The compressor is designed to
operate with certain speeds and mountings. If the operating
speed is too slow, insufficient air supply may result. On the
other hand, a very high speed will shorten compressor life.
Use the following information as a guide when installing an
EL1300, EL1600 or EL3200 Compressor:
Maximum Allowable Compressor Speed
Maximum Radial Force On Crankshaft
Maximum Pulley Offset
T 3
T = 240# MÁX.
T 4
T 1
T 2
3# MÁX.
Governor Mounting
A. Inspect the reservoir to governor line. The line must
be free of contamination and kinks.
CAUTION The exhaust port of any governor must be open
!
to the atmosphere. If the reservoir to governor line is too
short, use kit SN4011F (this will add eight inches to the line).
B. Keep Governor as Close To Compressor as Possible.
The line between compressor governor and unloader
must not be greater than 5/16 inch ID or longer than five
feet. Erratic governor performance may result when the
discharge line is beyond those limits.
C. Keep Governor Away from Engine Hot Spots.
Excessive heat is detrimental to the rubber seals in the
governor; therefore, some thought should be given as to
its location. This also applies when mounting the
governor to the compressor – the governor should be
placed as far from the compressor discharge as possible.
D. Governor Supply Line Must Be 1/4 Inch ID Minimum.
When the governor opens, air passes through the gover-
Filter
nor and fills the unloader pins cutting out the compressor .
If the governor supply line is restricted, a pressure loss at
the governor supply may close the governor valve and
exhaust the air in the unloader. As soon as pressure builds
up again at the governor, it will reopen. This cycle will con-
tinue at a high rate. To avoid this "flutter" condition, the
governor line should be at least 1/4 inch ID and should not
be restricted by fittings or sharp bends. It is also recom-
mended that this line be as short as possible and be inde-
pendent from other accessories requiring a supply of air .
Exhaust Line
Reservoir Drains
A. Close before starting engine.
3000 rpm
Start Engine
240 lbs.
3 inches
A. Inspect installation for air pressure, coolant or oil leak-
age. Listen for any noise which may indicate loose
mounting or poor drive gear alignment.
Governor Function
A. Build up air system. Observe cut out pressure (maximum
system pressure), "pump" foot control valve until compres-
sor starts pumping again (minimum system pressure). The
most common pressure range is 105 to 125 psi. Your fleet
may require different pressure levels which can be adjusted
by changing the governor setting.
Unloader
Unloader Line
Governor
Governor
Supply Line
Air Reservoir
Installation / Changeover
Instructions for 4-Hole or 6-Hole
Base Mount, Water Cooled
For Cat Mount 3208 Ford,
Use Mounting Plate Kit SN3722
EL13060
EL13060X
EL16060
EL16060X
L31030W
Rev. 5/02

Publicidad

loading

Resumen de contenidos para Haldex EL13060

  • Página 1 If intake vacuum exceeds 20 inches of water , the governor; therefore, some thought should be given as to intake filter must be changed. Haldex compressors in the its location. This also applies when mounting the EL or EL(X) series may be supercharged up to 35 psi inlet governor to the compressor –...
  • Página 2 1. Is the compressor a top head discharge? Adapter Plate Kit. Remove and discard the existing alu- minum plate. Replace with the steel Haldex SN3722 plate. 1. If top discharge, supply SN3711J Manifold Kit. 2. If compressor is a side head discharge, is there clear- ance for a top head discharge installation? 2.
  • Página 3 WATERLINE Increase Air Flow SN4011F CHANGEOVER KIT The Haldex recommended manifold kit offers a smoother and less abrupt change in direction of discharge air flow . The Haldex recommended manifold will give a quicker air delivery FLEXIBLE DISCHARGE and reduce carbon buildup over a longer period of time.
  • Página 4 Coolant Coolant Out Coolant In A. See front side for Haldex recommendations. The line 6. Retorque the head bolts to 27 – 33 ft. lbs. in the same must be .547 inch ID Minimum, show no bends smaller order as shown in the sketch above.
  • Página 5 Si el vacío de entrada excede las 20 pulgadas de agua, el filtro de motor. El calor excesivo es dañino para los sellos de caucho del entrada se debe cambiar. Los compresores de Haldex de las series gobernador. Por lo tanto, analice bien el lugar del mismo antes de EL o EL(X) se pueden cargar a una presión de entrada de aire de...
  • Página 6 Retire y deseche la placa de aluminio existente. Reemplácela con la placa SN3722 de acero de Haldex. 3. ¿ Son todos los puertos de agua de ½" NPT? 2. Si el espacio del cabezal superior es un problema, deberá contar con un juego de descarga de perfil bajo SN371 1K o SN3711L.
  • Página 7 Incremento del flujo de air e SN4011F CONDUCTOS DE AGUA El juego de distribuidor recomendado Haldex ofrece un cambio más suave y menos abrupto en la dirección del flujo de aire de descarga. El distribuidor recomendado Haldex ofrece un suministro de aire más rápido y reduce la acumulación de carbono durante períodos largos.
  • Página 8 Desmontaje A. Consulte las recomendaciones de Haldex que se encuentran en la refrigerante refrigerante parte lateral frontal. El conducto debe tener un diámetro interior de ADVERTENCIA Coloque el vehículo sobre una superficie 0.547" como mínimo y la curvatura no debe ser inferior a 2" de nivelada.

Este manual también es adecuado para:

El13060xEl16060El16060x