-
take steps to prevent the power from being reconnected;
-
open the terminal box only after making sure the power is disconnected.
9.4
RESIDUAL RISKS
When designing the machines or systems on which the blower is to be installed, the following residual risks must be considered.
Danger due to hot surfaces!
In operation the unit may overheat, exposing the operator to contact with hot surfaces.
Do not touch the unit when in operation.
Before carrying out any operation after shutdown allow the unit to cool by waiting at least 20 minutes.
Danger due to rotating parts: electric motor cooling fan.
Although designed to reduce any danger, the machine has residual risks linked to the rotation of the fan.
Precautions to be taken:
-
Do not wear loose fitting clothes
-
Do not go near the machine with long and loose hair
Danger due to noise from the unit!
Some machines can produce high noise levels, even exceeding 80 dB(A).
The reference values are given in the specifications, which do not consider environmental reverberation.
Precautions to be taken:
Check the actual sound pressure of the machine in the place, and if necessary:
-
Report the foreseen noise risk
-
Arrange the use of PPE
-
Insulate the place
10 FORESEEN USE
FPZ side channel blowers / exhausters are designed to generate vacuum and overpressure and for conveying non-explosive, non-
flammable, non-toxic and non-aggressive gases and air in continuous duty in a non-explosive environment.
FPZ side channel blowers / exhausters are designed and built for use in industrial plants and are equipped with three-phase or single-
phase asynchronous bipolar electric motors in compliance with IEC 60034-1.
10.1
CONDITIONS OF USE
Non-compliance with the unit's intended use can cause serious accidents.
This manual:
MUST be read carefully and understood before carrying out any operations on the unit;
MUST be strictly complied with;
MUST always be at hand in the place where the unit is used.
Installation must only be carried out by qualified personnel.
ATTENTION!
If installation is outdoors, protect the unit from the sun.
If installation is outdoors, protect the unit from the sun.
The maximum permissible pressure differentials given in the "SPECIFICATIONS" must never be exceeded. They are valid only under
the following conditions;
as a blower:
FPZ-MI-K-TD-MOR-IE2WR-15-R02
32 / 117