Remove and refit the housings and blind flanges according to the following diagram to obtain the desired configuration
Removing the blind flange (B)
Place the unit horizontal, resting the feet on a flat and stable surface.
Undo the screws and remove the blind flange and gasket
Removing the silencer housing (C)
Undo the screws.
Remove the silencer housing with gasket.
Removing the flange (D)
Undo the screws.
Remove the flange and gasket.
Reassemble by proceeding in reverse order,
remembering the gaskets.
Danger due to rotating parts: impeller!
The danger of shearing due to the rotating impeller can exist even when the machine off, if it is started manually.
Therefore use suitable work clothes and personal protection equipment.
12.3.1
90° MANIFOLD (accessory) USE (K-MS MOR)
For different connection configurations, use the 90° manifold installed
only on the cover openings.
See the possible configurations as previously illustrated.
Fitting the 90° manifold
Remove the silencer as previously described.
Insert the gaskets between the cover and manifold.
Tighten the respective screws
Assemble the silencer by proceeding in reverse order.
See par. 5.1 for INSTALLATION CONDITIONS
FPZ-MI-K-MS-MD-MOR-IE2WR-15-R02
A
C
42 / 126
A
B
D