Anleitung Euro 4000
GB
Explanation of the compressed
air fittings
1 Pressure switch
2 Safety valve
3 Pressure gauge (to indicate the
vessel pressure)
4 Pressure gauge (to indicate the
set pressure)
5 Pressure reducing valve
(pressure setting)
6 On/Off switch
Maintenance and
cleaning
G Condensation water
Let out the condensation water
daily by opening the drain valve
(bottom of the pressure
vessel).
G Safety valve
The safety valve is set to the
maximum pressure of the
pressure vessel. It is prohibited
to adjust the safety valve or to
remove its lead seal.
To ensure that the safety valve
works properly in the event of
an incident you should actuate
it from time to time. To do so,
turn the knurled screw
anticlockwise until you can
hear compressed air being
blown out. Then turn the
knurled screw clockwise as far
as the stop and tighten by
hand.
G Regular oil level checks
The level of oil has to be visible
in the sight-glass between the
red check-point mark and the
upper edge of the sight-glass.
Changing the oil:
Recommended grade SAE
15W/40 or equivalent.
The first oil change should be
carried out after 100 operating
hours. Thereafter you should
drain the oil and replace it with
new oil at intervals of 500
operating hours.
10
09.11.2001 9:37 Uhr
G Changing the oil
Switch off the motor and pull
the power plug out of the
socket-outlet. After letting off
any air pressure you can
remove the oil drain plug (sight-
glass) from the compressor
pump by unscrewing. To
prevent the oil escaping out of
control, hold a small piece of
metal guttering underneath the
drain plug to direct the oil into a
container.
If any oil still remains inside, tilt
the compressor a little.
Take the old oil to an official
old oil disposal station.
When the old oil has run out,
screw the oil drain plug/sight-
glass back in place.
Use a screwdriver to remove
the cap of the oil filler plug and
fill in oil until the level of oil in
the sight-glass reaches the red
mark.
Then put the cap back on the
oil filler plug.
4
1 Filter
2 Oil drain plug / sight-glass
3 Oil filler plug
Seite 10
G Cleaning the intake filter
The intake filter prevents dust
and dirt being drawn into the
machine. This filter has to be
cleaned at intervals of no
longer than 300 operating
hours. A clogged intake filter
has a considerable negative
effect on the compressor's
power.
The filter can be removed as
shown in Figure 4. Wash out
the filter with petroleum ether
and reinsert.
Caution! Wait until the
compressor has cooled
completely!
Risk of burns!