Westinghouse Swirl Manual Del Usuario
Ocultar thumbs Ver también para Swirl:

Publicidad

Enlaces rápidos

OWNER'S MANUAL
MANUAL DEL USUARIO
Swirl
Please write model number here for future reference:
Por favor, incluya el número del modelo aquí para futura referencia:
UL-ES-AC-Swirl-WH19.09
Net Weight:
20.66 LBS
Peso Neto:
9.39 KGS

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Westinghouse Swirl

  • Página 1 UL-ES-AC-Swirl-WH19.09 OWNER'S MANUAL MANUAL DEL USUARIO Swirl Please write model number here for future reference: Por favor, incluya el número del modelo aquí para futura referencia: Net Weight: 20.66 LBS Peso Neto: 9.39 KGS...
  • Página 2: Safety Tips

    UL-ES-AC-Swirl-WH19.09 SAFETY TIPS OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED 'ACCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS' AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE.
  • Página 3: Consejos De Seguridad

    UL-ES-AC-Swirl-WH19.09 CONSEJOS DE SEGURIDAD HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O HERIDAS GRAVES PERSONALES, MONTE EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA VENTILADORES DE 35 LB (15,9 KG) O MENOS” UTILIZANDO LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR Y/O MONTE DIRECTAMENTE EN LA ESTRUCTURA DEL EDIFICIO. LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS NORMALMENTE CON ARTEFACTOS DE ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS.
  • Página 4 UL-ES-AC-Swirl-WH19.09 FEATURES CARACTERÍSTICAS SLOPED CEILING DOWNROD INSTALLATION INSTALLATION FLUSH MOUNT INSTALLATION INSTALACIÓN PARA INSTALACIÓN CON INSTALACIÓN AL TECHO VARILLA VERTICAL TECHO INCLINADOS For low ceilings For normal ceilings May require a longer downrod (sold separately) Para techo bajos Para techo normales Podría requerir una varilla vertical más larga...
  • Página 5 UL-ES-AC-Swirl-WH19.09 FEATURES CARACTERÍSTICAS COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor, or change the style with just a flip of the blade. NOTE: Combo-Blade finishes vary, depending upon model. ALETAS DE DOBLE CARA Las aletas del rotor de doble cara presentan dos superficies con un acabado de alta calidad.
  • Página 6 UL-ES-AC-Swirl-WH19.09 PREPARING FOR INSTALLATION ANTES DE LA INSTALACIÓN Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member (a loose box will cause the fan to wobble).
  • Página 7 UL-ES-AC-Swirl-WH19.09 MOUNTING BRACKET INSTALLATION INSTALACIÓN CON SOPORTE DE MONTAJE Remove the screws and star washers from the two mating holes (1) on the canopy. Loosen (do not remove) the screws in the mating slots (2) on the canopy. Rotate the mounting bracket counter-clockwise and remove from the canopy.
  • Página 8 UL-ES-AC-Swirl-WH19.09 MOUNTING BRACKET INSTALLATION MOUNTING OPTIONS INSTALACIÓN CON SOPORTE OPCIONES DE MONTAJE DE MONTAJE Choose a MOUNTING OPTION Elija una OPCIÓN DE MONTAJE FLUSH MOUNT OPTION If flush mount option is selected, proceed to page 9, step 6. OPCIÓN DE INSTALACIÓN AL TECHO Si elige la opción de montaje al techo,...
  • Página 9 UL-ES-AC-Swirl-WH19.09 FLUSH MOUNT OPTION OPCIÓN DE INSTALACIÓN AL TECHO For flush mount option, raise fan assembly and place onto hook from mounting bracket into a closed hole on the canopy. This will allow for hands free wiring. Guide motor wires through the base of the canopy as shown and attach canopy PROCEED DIRECTLY TO PAGE 14 FOR WIRING OPTIONS.
  • Página 10 UL-ES-AC-Swirl-WH19.09 NORMAL DOWNROD OPTION EXTENDED DOWNROD OPTION OPCIÓN CON VARILLA VERTICAL OPCIÓN CON VARILLA PARA TECHO NORMAL VERTICAL MÁS LARGA Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod.
  • Página 11 UL-ES-AC-Swirl-WH19.09 EXTENDED DOWNROD OPTION OPCIÓN CON VARILLA VERTICAL MÁS LARGA Re-install pin into extended downrod, and slide downrod ball up to the top of the downrod. Re-install set screw to secure ball to downrod. Note: Some extended downrods have a pre-drilled set-screw hole.
  • Página 12 UL-ES-AC-Swirl-WH19.09 EXTENDED DOWNROD OPTION OPCIÓN CON VARILLA VERTICAL MÁS LARGA Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke.
  • Página 13 UL-ES-AC-Swirl-WH19.09 MOUNTING MONTAJE Carefully lift fan assembly onto mounting bracket. Rotate fan until notch on downrod ball (1) engages the ridge on the mounting bracket (2). This will allow for hands free wiring. With bracket holding fan assembly, make electrical connections using the Levante con cuidado el conjunto del ventilador hasta el soporte de montaje.
  • Página 14 UL-ES-AC-Swirl-WH19.09 WIRING OPTIONS OPCIÓN DE CABLEADO PULL CHAIN WIRING OPTION WALL CONTROL WIRING OPTION Follow diagram above to make wiring connections for fan pull chain control. Follow diagram above to make wiring connections for wall control operation. OPCIÓN DE CABLEADO PARA CONTROL DE PARED OPCIÓN DE CABLEADO PARA CADENILLA DE TIRO...
  • Página 15 UL-ES-AC-Swirl-WH19.09 SECURE TO CEILING ASEGURE EL VENTILADOR AL TECHO For flush mount fans, carefully lift fan up to the mounting bracket, making sure not to break any wire connections. For downrod fans, slide the canopy up to the mounting bracket.
  • Página 16 UL-ES-AC-Swirl-WH19.09 BLADE INSTALLATION INSTALACIÓN DE LAS ALETAS Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise-dampening motor gaskets (2) and motor screws provided. Tighten screws securely.
  • Página 17 UL-ES-AC-Swirl-WH19.09 LIGHT FIXTURE INSTALLATION INSTALACIÓN DEL ARTEFACTO LUMINOSO Find the two wires from the switch housing with the tag that says FOR LIGHT. Connect the black wire from the switch housing to the black wire from the light kit, and...
  • Página 18 UL-ES-AC-Swirl-WH19.09 OPERATION AND MAINTENANCE Operation Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse.
  • Página 19: Operación

    UL-ES-AC-Swirl-WH19.09 OPERACIÓN Y MANTENIMIENTO Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado.
  • Página 20: Troubleshooting Guide

    UL-ES-AC-Swirl-WH19.09 If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these TROUBLESHOOTING GUIDE installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, please consult with your qualified electrician and do not attempt any electrical repairs yourself.
  • Página 21 UL-ES-AC-Swirl-WH19.09 Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o cableado incorrectos. En algunos GUÍA PARA SOLUCIONAR PROBLEMAS casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar problemas.
  • Página 22 UL-ES-AC-Swirl-WH19.09 PARTS LIST LISTA DE REPUESTOS Description 1 ..... . Mounting Bracket 2 ..... . Blade Bracket 3 .
  • Página 23: Garantía

    If replacement product is not available through seller, please contact www.westinghouselighting.com/contact-us. GARANTÍA Este ventilador de Westinghouse Lighting se ofrece con una garantía limitada de por vida para el propietario original frente a defectos de material y de mano de obra. Esta garantía sustituye cualquier otra garantía expresa o implícita.
  • Página 24 UL-ES-AC-Swirl-WH19.09 Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com , WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation. Used under license by Westinghouse Lighting All rights reserved. Made in China...

Tabla de contenido