Wiring Diagrams and Instructions – LER*4B, LESQ*4B, LER*6B, & LESQ*
Catalog Number
Outer
Diameter
LER(WM)S4B
LER(WM)4B
5.3" (135.6 mm)
LERUDS4B
LERUD4B
LESQ(R)(WM)S4B
LESQ(R)(WM)4B
5.6" (142.2 mm)
LESQ(R)UDS4B
LESQ(R)UD4B
LER(WM)S6B
LER(WM)6B
6.6" (166.6 mm)
LERUDS6B
LERUD6B
LESQ(R)(WM)S6B
LESQ(R)(WM)6B
6.6" (167.1 mm)
LESQ(R)UDS6B
LESQ(R)UD6B
INSTALLATION
N
ote:
LED and Trim assembly to be installed only after
cylinder is installed.
Surface Mount Cylinders
1.
Remove locking screw.
2.
Rotate the mounting plate in anticlockwise direction to
separate from assembly and to remove from cylinder.
(Figure 1.)
3.
Attach mounting plate to Junction Box.
4.
Attach tether under one Junction Box mounting screw.
(Figure 4.)
5.
Wire Unit per Wiring Diagram (refer to electrical section).
Push wiring into Junction Box.
6.
Insert tabs from mounting plate in to cylinder top. Rotate
cylinder clockwise to engage hooks.
7 .
Ensure holes are aligned, install Locking screw.
8.
For Wet Location/IP66 Installer must apply silicone
compound around the perimeter of the mounting plate in
contact with the ceiling.
9.
Also for Wet Location/IP66 Installer must apply silicone
compound are the perimeter of the mounting plate in
contact with the cylinder top.
Wall Mount Cylinders
1.
Install wall mounting plate to splice box using splice box
hardware (provided by others) and tighten to 17 IN/LBS
torque when using 8-32 screw. (Figure 2.)
2
Cooper Lighting Solutions
Height
Ceiling Mounts
Wall Mounts
6.8" (171.8 mm)
6.0" (152.6 mm)
12.4" (314.4 mm) 11.5" (292.5 mm)
12.5" (317.5 mm)
20.2" (512.6 mm)
6.8" (171.8 mm)
6.0" (152.6 mm)
12.4" (314.4 mm)
11.5" (292.5 mm)
12.5" (317.5 mm)
20.2" (512.6 mm)
8.1" (205.9 mm)
6.7" (171.1 mm)
14.1" (357.4 mm)
12.7" (322.6 mm)
11.2" (283.7 mm)
23.1" (586.0 mm)
7.6" (194.1 mm)
6.3" (159.3 mm)
13.8" (351.4 mm) 12.5" (316.6 mm)
11.2" (283.7 mm)
23.1" (586.0 mm)
IB520075ML
Installation instructions
Figure 1.
Figure 2.
Luminaire Quick
Disconnect
LED Engine
Trim Assembly
Figure 3.
Figure 4.
Fiberglass
Sleeve
Torsion Springs