Step 3: Installation - Thermador VTR630P Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Step 3: INSTALLATION

1. Hold the blower on the wall.
Note the direction of the air conduction.
2. Mark the 4 mounting boreholes.
At least one screw must be installed through a
stud.
All hardware must be suitable for the wall's
construction materials.
Ensure the air outlet points downward.
3. Wall break:
Mark and drill a guide hole and a separate hole for
electrical conduit.
4. Drill the 4 x ¼'' (6,3 mm) Ø mounting boreholes.
Insert wall anchors and screw the blower to the wall.
5. Connect the ducting from the blower to the extractor
hood and feed to the outside.
min. 40"
min. 40"
min. 40"
(101.5 cm)
(101.5 cm)
(101.5 cm)
min. Ø 6½"
min. Ø 6½"
min. Ø 6½"
(16.5 mm)
(16.5 mm)
(16.5 mm)
10⅞"
10⅞"
10⅞"
(276 mm)
(276 mm)
(276 mm)
5¼"
5¼"
5¼"
(133 mm)
(133 mm)
(133 mm)
5
5
5
"
"
"
8 8
/
/
/
16
16
16
(211 mm)
(211 mm)
(211 mm)
13
13
13
"
"
"
/
/
/
16
16
16
(21 mm)
(21 mm)
(21 mm)
min. Ø ¾"
min. Ø ¾"
min. Ø ¾"
(19 mm)
(19 mm)
(19 mm)
½"
½"
½"
(12.7 mm)
(12.7 mm)
(12.7 mm)
"
"
"
3 3
15
15
15
/
/
/
16
16
16
(100 mm)
(100 mm)
"
"
"
16
16
16
11
11
11
/
/
/
16
16
16
(424 mm)
(424 mm)
English 3