9. What if there are problems?

If the time is not displayed correctly or the device does not
function correctly, the cause may be attributed to electro-
static discharge or other faults. Therefore, do not position
the device near to other devices, such as WLAN etc. To
remedy the problem, reset the device to the factory settings.
To reset the device to the factory settings, press in the
reset button on the underside of the device using a poin-
ted object.
If the problem persists, contact Customer Services.

10. Technical data

Wake up light function
Snooze duration
Goodnight function
Dimensions
OFF, 15, 30 minutes before
alarm
5 to 60 minutes
Choose between 5, 10, 15,
30, 45, 60, 75, 90 minutes and
OFF.
12.3 x 12 cm
Weight
Supply
Mains part
Protection class
Radio frequency range
Illuminance
Average active effi-
ciency
No-load power con-
sumption
Mains part
Subject to technical changes.
23
180 g
Input: 100 - 240 V; AC 50/60 Hz,
max. 200 mA
Output: 5,5 V; DC 500 mA
(0,5 A); 2,75 W
Protection class II
87,5 – 108 MHz VHF
approx. 15 Lux (at distance of
15 cm)
≥ 73.80 %
≤ 0.1 W
Manufacturer:
Hong Kong Yee Fu Electronic
Enterprises Co., Ltd.
Adresse: Room 6,
Smart-Space 1, Units 401-403,
Level 4, Cyberport 1, 100
Cyberport Road, Hong Kong
Model no.: L008A055050E