Technical data
Weight in working order
Height
Depth
Width
Platen size
Power supply
Power consumption
Amp rating
Power supply (US version)
Power consumption (US version)
Amp rating (US version)
Air supply
Pressing
Membrane inflation (Air Pro)
Electronic temperature controller
Accuracy
Setting range
Electronic timer
Accuracy
Setting range
Operating conditions
Noise level
Ambient operating temperature
Humidity
Maximum pressing force
Non-contractual document : we reserve the right to alter our product specifications in
line with advances in technology.
www.sefa.fr
TECHNICAL DATA
193 kg
751 mm
1005 mm
1071 mm
400 x 500 mm
220/240 V single phase + ground 50/60 Hz
3200 W
14 A
110/120 V single phase + ground 50/60 Hz
1750 W
16 A
4 - 8 bars
2 - 7,5 bars (membrane : 8 bars)
0,5 bars
+/- 1%
0 °C - 220 °C
+/- 1%
0 s - 59 min 59 sec
< 70 dB (A)
10 °C - 35 °C
< 90%
925 daN
User guide - SEFA DUPLEX V3 Series