1 WARNING
Before performing any operation on the machine,
make sure that you have thoroughly read and
understood the contents of this booklet.
Do not perform modifications or maintenance
operations which are not prescribed.
The manufacturer cannot be held responsible for damages to
persons or property caused by misuse or non-application of the
contents of this booklet by the user.
Please consult qualified personnel if you have any
doubts or difficulties in using the equipment.
1.1 Work environment
• This equipment shall be used for professional applications
only, in industrial environments.
The manufacturer shall not be held responsible for any damages
caused by the use of the equipment in domestic environments.
• The equipment must be used in environments with a tem-
perature between -10°C and +40°C (between +14°F and
+104°F).
The equipment must be transported and stored in envi-
ronments with a temperature between -25°C and +55°C
(between -13°F and 131°F).
• The equipment must be used in environments free from dust,
acid, gas or any other corrosive substances.
• The equipment shall not be used in environments with a rela-
tive humidity higher than 50% at 40°C (104°F).
The equipment shall not be used in environments with a rela-
tive humidity higher than 90% at 20°C (68°F).
• The system must not be used at an higher altitude than 2,000
metres (6,500 feet) above sea level.
2 RC 100
2.1 General
Operation of the remote control is activated when connected to
the power sources. This connection can be made also with the
system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
2.2 Control panel
The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
1
Green LED
When on, it means the output current display and its
adjustment is enabled.
2
Green LED
When on, it means the output voltage display is ena-
bled.
3
When on, it means the output power is enabled.
4
7-segment display
It shows general power source information during start-
up, during welding operations (settings and readings of
output current and voltage) and during fault conditions
(alarm codes).
5
Encoder key
It enables set up menu entry and welding parameters
selection/setting.