31. Never defeat the safety fea tures of
this product.
32. Do not op er ate machine with
missing, broken or un au tho rized
parts.
33. Never spray flammable liquids
or use pressure washer in areas
containing
liquid, or vapors.
WARNING: Risk of injection or
injury. Do not direct discharge stream
at persons.
Save theSe
inStructionS
SAFETY FEATURES
AUTOMATIC TOTAL STOP
The pressure washer is equipped with
a stop device which will sense when
the trigger on the gun is released. It will
open the power circuit to the motor and
cause the pressure washer to stop.
WARNING: If Automatic Total Stop
fails to operate, DO NOT USE THE
MACHINE. Contact our customer
service department. Further use will
damage the machine and/or cause
personal injury.
WARNING: The pressure washer
is also equipped with a main power
ON/OFF switch located on the unit. It
should always be moved to the OFF
position when the pressure washer is
not being used to prevent possible
injury or damage.
MOTOR OVERLOAD
The electric motor in this pressure washer
is equipped with an overload protection
device which will automatically shut off
the motor in the event the motor draws
excessive current or overheats. The
device will automatically reset itself and
resume normal operation after a short
period of time.
combustible
dust,
®
GROUND-FAULT CIRCUIT
INTERRUPTER PROTECTION
This pressure washer is provided with a
Ground-Fault Circuit-Interrupter (GFCI)
built into the plug of the power supply
cord. This device provides additional
protection from the risk of electric
shock. Should replacement of the plug
or cord become necessary, use only
identical replacement parts that include
GFCI protection.
SERVICING A DOUBLE INSULATED
APPLIANCE
In a double-insulated product,
two systems of insulation are
provided instead of grounding.
No
provided on a double-insulated product,
nor should a means for grounding be
added to the pressure washer.
Servicing a double-insulated product
requires extreme care and knowledge
of the system, and should be done only
by qualified service personnel.
Replacement parts for a double-
insulated product must be identical to
the parts they replace.
A double-insulated product is marked
with the words "DOUBLE-INSULATION"
or "DOUBLE-INSULATED". The symbol
above may also be marked on the
product.
POWER SUPPLY AND
ELECTRICAL INFO
GROUND-FAULT CIRCUIT
INTERRUPTER PROTECTION
The pressure washer is factory-
equipped with an electrical cord and a
Ground Fault Circuit Interrupter (GFCI)
power plug. This cord should only
be connected to an electrical outlet
installed in accordance with local safety
regulations.
NOTE: The power supply must be
120 V, 60 Hz and a minimum 15 amp
dedicated circuit.
6- ENG
grounding
means
is