CONFORMITY DECLARATION
The manufacturer declares that the appliances are in accordance with the EEC 90/396 directive provisions. The installation
must be carried out in observance of the standards in force above all regarding the airing of the rooms and the evacuation
system of the exhaust gases.
N.B. The manufacturer declines all responsibility for direct or indirect damage caused by incorrect installation, alterations,
poor maintenance, incorrect use and all the other cases provided for in the articles stated in our sales conditions
INSTALLATION
MODEL
BM - 4G
BM - 6G
BM - 8G
INSTALLATION OF THE APPLIANCE
•
Installation, any transformations for other types of gas and starting can be done only by qualified personnel according
to the standards in force.
•
The gas systems, electrical connections and the rooms where the appliances are installed must be in accordance with
the standards in force in the country where they are installed; particularly, the appliance must be installed in a well
aired room, possibly under a suction hood to guarantee complete evacuation of the exhaust gases that are formed
during combustion; the necessary air for combustion is 2 m
When installing the appliance, a maximum distance must be kept between the front edge of the cabinet or table on which
the appliance is standing and the front of the appliance itself. (See diagram inder "Emptying the Tub").
CHECKING FOR ADEQUATE VENTILATION
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.
1) Installation rules
The installation and maintenance of the appliance must be done according to the correct procedures and regulation
texts in use, particularly:
•
safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer' s instructions and by qualified technicians and according to the regulations in effect. The electric wiring shall
conform to the regulations in effect. All fire prevention codes shall be observed.
a)
General indications (Rules valid for G.B. only)
-
For all appliances:
Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The Building
Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-laws of the local Water
Undertaking.
The local gas Region or LPG supplier and the local authority and the relevant recommendation of the British Standards
(latest editions) concerned.
The installation, transformation and repair of appliances for professional kitchens as well as removal due to malfunction,
and the supply of gas, may be made only by means of a maintenance contract stipulated with an authorised sales office
and in observance of technical regulations.The appliance can be installed by itself or in a series side by side with appliances
produced by us. There must be a minimum distance of at least 10 cm between the appliance and the sides of the nearby
cabinets made of inflammable material. Take suitable measures to guarantee thermal insulation of the inflammable sides,
such as, for example, the installation of protection against radiaton. The appliances must be installed in a suitable manner,
observing the safety standards. The small feet are adjustable to level the appliance.
GB
IE
DIMENSIONS
CONNECTION
ISO R7
40x65x29h
R 1/2"
60x65x29h
R 1/2"
80x65x29h
R 1/2"
/h per kW of installed power.
3
26
TOTAL
GAS
NOMINAL
POWER kW
3,5
5,0
6,5