EXTENSION CORdS
Use proper extension cords. Make
sure your extension cord is in good
condition and is a 3-wire extension cord which has a
3-prong grounding type plug and matching
receptacle which will accept the machine's plug.
When using an extension cord, be sure to use one
heavy enough to carry the current of the machine.
An undersized cord will cause a drop in line voltage,
resulting in loss of power and overheating. Fig. C
shows the correct gauge to use depending on the
cord length. If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the cord.
FOREWORd
Model 50-875 Type II DELTA
circulate and filter non-metallic dust which is generated throughout the work area. The Air Cleaner is furnished
with two filters: an outer filter which filters particles that are five microns and larger, and a secondary disposable
filter that captures 91% of the dust particles that are one micron and larger (one micron = one millionth of a meter).
Because breathing microscopic particles can be a potential health hazard, filtering microscopic dust particles
offers a cleaner and safer environment. This Air Cleaner will filter the air in a room measuring 20' x 20' x 8' either
13, 16, or 18 times an hour, depending on the setting. If desired, multiple units can be used to filter larger areas. An
occasional cleaning and/or replacement of filters is the only required maintenance.
FIg. 1A
1. Air cleaner
FUNCTIONAL dESCRIPTION
3 Speed Ambient Air Cleaner with Pleated Filter is specifically designed to quietly
®
CARTON CONTENTS
MINIMUM gAUgE EXTENSION CORd
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
volts
Rating
0-6
120
0-6
120
0-6
120
0-6
120
120
6-10
6-10
120
6-10
120
6-10
120
10-12
120
10-12
120
10-12
120
10-12
120
12-16
120
12-16
120
12-16
120
2. Remote Control Unit
(Batteries not included)
3. 1" Eye-Bolts (4)
4. Rubber Feet (4)
5. 5/16" Flange nuts (4)
5
Total Length
gauge of Extension
of Cord in
Cord
Feet
up to 25
18 AWg
25-50
16 AWg
50-100
16 AWg
100-150
14 AWg
up to 25
18 AWg
25-50
16 AWg
50-100
14 AWg
100-150
12 AWg
up to 25
16 AWg
25-50
16 AWg
50-100
14 AWg
100-150
12 AWg
up to 25
14 AWg
25-50
12 AWg
gREATER THAN 50 FEET NOT RECOMMENDED
FIg. C
FIg. 1B