9.
INSTALLATION OF FAN UNIT
1.
Unhook the cover (2) from the motor support by pressing on the side holes (1) using a small screwdriver
(Figure 8).
2.
Fracture the shutter provided for the transfer of connections (3), in the case of non-concealed external
connections, fracture the zones provided for (4) both on the motor support and on the cover (Figure 9).
3.
Fix the motor support at the evacuation hole with screws and raw plugs (Figure 10).
4.
Place the power cable in the appropriate place (Figure 11).
2
1
16
1
Figure 8
Figure 10
E N G L I S H
ECOCOMFORT Series
3
4
4
4
Figure 9
Figure 11