Operation (continued)
3
Setting the Sensor for Testing
When the "ON-TIME" switch is set to the "TEST"
position, the light fixture will operate during the day
or night. The light will stay on for 5 seconds after all
motion is stopped.
Set the "ON-TIME" switch to the "TEST" position.
Set the "DUALBRITE" switch to the "OFF"
position.
Turn the "RANGE" dial to the "MIN" position.
Aim the motion sensor (C) in the general
direction of the area to be covered.
NOTE: The motion sensor will need to completely warm
up (90 seconds) before beginning the setup process.
LAMP MODE
NORMAL SOFT FLASH
ON-TIME
DUAL BRITE™
MIN
MAX
TEST 1 5 20
OFF 3 6 DUSK TO
RANGE
MINUTES
HOUR
5
Adjusting the RANGE Dial
To increase the detection zone, turn the
"RANGE" dial toward the "MAX" position.
To decrease the detection zone, turn the
"RANGE" dial toward the "MIN" position.
NOTE: The motion sensor (C) is more sensitive to motion
moving across the front of the sensor. The motion sensor
(C) is less sensitive to motion moving directly toward the
front of the sensor.
NOTE: The higher the "RANGE" setting (sensitivity), the
greater the possibility of false triggering. To reduce false
triggering, rotate the "RANGE" control toward the "MIN"
setting.
MIN
MAX
RANGE
C
DAWN
C
Adjusting the Motion Sensor
4
Detection Zone
Turn on the circuit breaker or fuse and the light
switch.
Perform a "walk test". Walk in an arc across
the front of the motion sensor (C).
Watch the light. The light will come on and the
red LED will flash indicating motion has been
detected.
Stop, wait for the light to turn off, and then
begin walking again.
Continue this process until the detection zone
has been established.
Adjust the sensor up, down, or side to side to
change the motion sensor (C) detection zone.
C
6
Adjusting the ON-TIME Switch
The "ON-TIME" switch determines the amount of time
the light will stay on full bright after all motion has
stopped.
Set the "ON-TIME" switch to the 1, 5, or 20
minute position.
ON-TIME
MIN
MAX
TEST 1 5 20
RANGE
8
LAMP M
NORMAL SO
MINUTES
C