13.0 GAS PRESSURE CHECK - continued
The pressure test
points are located as
shown in figure 8. An
alternative
burner
(mainfold test) point
is located below the
left hand side of the
burner as shown in
figure 9.
The
pressure
regulator on manual
models is preset and
locked
to
avoid
Regulator
tampering.
If
the
pressure
pressure is not as
setting
specified
in
the
Appliance Data sec-
tion on page 2,
replace the regulator
with
P/N
FT/F730039.
Replace
the
test
point screws after
pressure
measurement
ensuring
no
gas
leaks. All instructions
must be handed to
the
user
for
safekeeping.

14.0 SPARK GAP

The gap between the
spark electrode and the
pilot should be 1/8" to
3/16" to produce a good
spark. There should be no
need to adjust this. If
under any circumstances
the piezo electric spark
fails, the pilot cannot be lit
manually.
.
Burner
(Manifold)
pressure
Spark gap
Figure 10

15.0 FITTING THE DECORATIVE FRAME

Figure 7
R e m o v e
decorative frame
assembly from any
p r o t e c t i v e
packaging,
r e m o v e
protective film that
may be present on
the
frame.
frame is hung onto
the firebox via the
two upper hanging
brackets and then
Figure 8
secured
to
firebox via the two
lower knurled fixing
bolts, which are
inserted
through
the holes in the
lower
mounting brackets
after the frame is in
position. See figure
11.
Figure 9

16.0 BRIEFING THE CUSTOMER

WARNING: DO NOT ADD LOGS OR ORNAMENTS SUCH
AS PINE CONES, VERMICULITE OR ROCK WOOL. USING
THESE ADDED ITEMS CAN CAUSE SOOTING.
All instructions must be handed to the user for safekeeping. Show the
customer how to light and control the fire. Show the customer how to
remove and replace the decorative frame.
After commissioning the appliance, the customer should be instructed
on the safe use of the appliance and the need for regular servicing.
Frequency of service depends on usage, but MUST be carried out at
least once annually.
Advise that cleaning of the fire may be achieved when the fire is cold
using a damp cloth and mild detergent on most surfaces.
Advise that the fire will emit a "newness" smell for a time after initial
commissioning and that extra ventilation may be needed during this
time. Recommend that a guard be used for the protection of the young,
pets, the elderly and the infirm. A periodic visual check of the pilot flame
and the burner flame should be carried out. (Refer to figure 15).

17.0 SERVICING

Isolate the fire from the gas supply. Ensure that the fire is fully cold
before attempting service. A suggested procedure for servicing is
detailed as follows;