Troubleshooting (continued)
Problem
Possible Cause
ELECTRICAL ISSUES CON'T.:
Burner(s) will not light
Wires are loose or disconnected.
using ignitor. (See
Integrated Ignition
Wires are shorting (sparking) between
Troubleshooting also).
ignitor and electrode.
Continued.
Dead battery.
Faulty electronic ignition circuit.
Sparking somewhere other than between
burner and electrode.
Burner(s) will not match
See "GAS ISSUES:" on previous page.
light.
Match will not reach.
Improper method of match-lighting.
Sudden drop in gas
Out of gas.
flow or low flame.
Excess flow valve tripped.
Vapor lock at coupling nut/LP tank
connection.
Flames blow out.
High or gusting winds
Low on LP gas.
Excess flow valve tripped.
Flare-up.
Grease buildup.
Excessive fat in meat.
Excessive cooking temperature.
Persistent grease fire
Grease trapped by food buildup around
burner system.
Flashback (fire in
Burner and/or burner tubes are blocked.
burner tube(s)).
Unable to fill LP tank.
Some dealers have older fill nozzles with
worn threads.
One burner does not
Grease buildup or food particles in end(s)of
light from other
carryover tube(s).
burner(s).
18
Prevention/Solution
Reconnect wires or replace electrode/wire assembly.
Replace ignitor wire/electrode assembly.
Replace with a new alkaline battery.
See Troubleshooting Integrated Electronic Ignition section.
Inspect wire insulation and proper connections. Replace wires if
insulation is broken.
Use long-stem match (fireplace match).
See "Match-Lighting" section of Use and Care.
Check for gas in LP tank.
Turn off knobs, wait 30 seconds and light grill. If flames are still low,
turn off knobs and LP tank valve. Disconnect regulator. Reconnect
regulator and leak-test. Turn on LP tank valve, wait 30 seconds and
then light grill.
Turn off knobs and LP tank valve. Disconnect coupling nut from tank.
Reconnect and retry.
Turn front of grill to face wind or increase flame height.
Refill LP tank.
Refer to "Sudden drop in gas flow" above.
Clean burners and inside of grill/firebox.
Trim fat from meat before grilling.
Adjust (lower) temperature accordingly.
Turn knobs to OFF. Turn gas off at LP tank. Leave lid in position and
let fire burn out. After grill cools, remove and clean parts.
Turn knobs to OFF. Clean burner and/or burner tubes. See burner
cleaning section of Use and Care manual.
The worn nozzles don't have enough "bite" to engage valve. Try a
second LP dealer.
Clean carryover tube(s) with a wire brush.