Problems And Solutions - Climadiff CLS52 Manual De Utilización

Cave a vin de service
Ocultar thumbs Ver también para CLS52:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

11. IN THE EVENT OF A BREAKDOWN
Despite the care we take during production, a breakdown can never be totally ruled out. Before contacting your
retailer's after-sales department, please check that:
-
the appliance is properly plugged in;
-
there is not a power cut in progress;
-
the breakdown is not one of those described in the table at the end of this manual.
IMPORTANT:
If the mains cable supplied is damaged, it must be replaced by the manufacturer, a centre approved by the brand
or by the retailer. In all cases, it must be replaced by qualified personnel, so as to avoid any risk of injury.
I
F THESE CHECKS REVEAL NOTHING
Unplug the appliance before carrying out any maintenance or repair work.

12. PROBLEMS AND SOLUTIONS

You can solve many simple problems with your wine cellar yourself, thus avoiding having to contact your after-
sales department. Try the following suggestions.
PROBLEM
The cellar will not start.
The cellar does not cool sufficiently.
The compressor starts and stops frequently.
The light does not operate.
Vibration.
The cellar makes a lot of noise.
The door does not close correctly.
,
THEN CONTACT YOUR RETAILER
CAUTION!
It is not plugged in.
The on/off button is in the off position.
The fuse in your electrical installation has blown.
Check the temperature selected.
The external temperature is beyond the cellar's operating
temperature.
The cellar is opened too often.
The door is not properly closed.
The door seal is not sealing correctly.
The external temperature is high.
A large quantity of bottles has been put into the cellar.
The cellar is opened frequently.
The door is not properly closed.
The cellar has not been correctly set.
The door seal is not sealing correctly.
The cellar is not plugged in.
The fuse in your electrical installation has blown.
The LED is not working.
The light switch is off.
Check and ensure that the cellar is level.
A noise resembling circulating water is produced by the
coolant gas and this is normal.
At the end of a cooling cycle, you can hear the noise of water
circulating.
Expansion and contraction of the internal walls may cause a
cracking sound.
The cellar is not level.
The cellar is not level.
The door seal is dirty or damaged.
The shelves are not positioned correctly.
A part of the contents is preventing the door from closing.
'
A
-S
D
S
FTER
ALES
EPARTMENT
POSSIBLE CAUSES
.
29

Publicidad

Tabla de contenido
loading

Tabla de contenido