Tabla De Contenido; Warnings And General Precautions; Safety Warnings; Product Description And Intended Use - Nice Hyke HK7024 Instrucciones Y Advertencias Para La Instalación Y El Uso

Motorreductor
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 55
ENGLISH
Instructions translated from Italian
Contents
Images
1 - WARNINGS AND GENERAL PRECAUTIONS ...................................... 1
1.1 - Safety warnings ..................................................................................... 1
1.2 - Installation warnings .............................................................................. 1
1.3 - Operation warnings ............................................................................... 1
2 - PRODUCT DESCRIPTION AND INTENDED USE ................................ 1
3 - INSTALLATION ...................................................................................... 2
3.1 - Preliminary installation checks ............................................................... 2
3.2 - Application limits ................................................................................... 2
3.3 - Preliminary installation set-up work ........................................................ 2
3.4 - Installation of gearmotor mod. HK7024 - HK7224 - HK7024HS -
HK7224HS .................................................................................................... 2
3.5 - Mechanical limit switch adjustment ........................................................ 3
3.6 - Manually releasing and locking the gearmotor ....................................... 4
4 - ELECTRICAL CONNECTIONS .............................................................. 4
HK7024HS .................................................................................................... 4
HK7224HS .................................................................................................... 4
4.3 - Connection of other devices .................................................................. 4
4.4 - Routing connected devices ................................................................... 5
4.5 - Initial start-up and connection check ..................................................... 5
4.6 - Learning of the connected devices ........................................................ 5
4.7 - Mechanical limit switch positioning learning ........................................... 5
4.8 - Gate leaf movement check .................................................................... 6
5 - TESTING AND COMMISSIONING ........................................................ 6
5.1 - Testing .................................................................................................. 6
5.2 - Commissioning ..................................................................................... 6
6 - CONTROL PANEL PROGRAMMING .................................................... 7
6.1 - Level 1 programming (ON-OFF functions) .............................................. 7
6.2 - Level 2 programming (adjustable parameters) ....................................... 8
6.3 - Special functions ................................................................................... 9
6.4 - Deleting the memory ............................................................................. 9
7 - TROUBLESHOOTING... (troubleshooting guide) ............................... 9
8 - FURTHER INFORMATION................................................................... 11
8.1 - Connecting a radio receiver ................................................................. 11
8.2 - Connecting and installing the buffer battery mod. PS124 .................... 11
8.3 - Connecting the Oview programmer ..................................................... 11
8.4 - Connecting the solar power system Solemyo ...................................... 11
8.5 - Connecting the external release system Kio ........................................ 11
9 - PRODUCT MAINTENANCE ................................................................ 12
PRODUCT DISPOSAL .............................................................................. 12
Product lifetime ........................................................................................ 12
TECHNICAL SPECIFICATIONS OF PRODUCT ....................................... 13
CE DECLARATION OF CONFORMITY .................................................... 14
APPENDIX .................................................................................................... I
Instructions and warnings for the user ........................................................... II
1

WARNINGS AND GENERAL PRECAUTIONS

1.1 - Safety warnings

• IMPORTANT! - This manual contains important instructions and
warnings regarding safety. Incorrect installation may cause serious injury.
Before commencing work, all sections of the manual must be read carefully.
If in any doubt, suspend installation and call the Nice Support Service for
clarification.
• IMPORTANT! - This manual contains important instructions. Keep it
for future maintenance work and disposal of the product.
• IMPORTANT! - Under the latest European legislation, automatic door
and gate installations must be compliant with the standards specified
in Directive 2006/42/EC (formerly 98/37/EC) (the Machinery Directive)
and the standards EN 12445, EN 12453, EN 12635 and EN 13241-1 in
particular, which enable conformity of the automated functionality to
be de clared. In the light of the above, all work involving installation,
connection, testing and maintenance of the product must be carried
out exclusively by qualified and competent technicians!
1.2 - Warnings for installation
• Before commencing the installation, check if the product is suitable for the de sired
type of use (see "Usage limitation" paragraph 3.2 and the "Product te chnical speci-
fications"). If it is not suitable, DO NOT continue with the installation.
• The contents of this manual refer to a standard system as described in fig. 3.
• All installation and maintenance work must be carried out with the
au to mation system disconnected from the electricity supply. If the
power discon nection device cannot be seen from where the automation sys-
tem is po sitioned, then before starting work a notice must be attached to the
disconnection device bearing the words "CAUTION! MAINTENANCE IN PRO-
GRESS".
• The Control unit must be connected to an electricity supply line equipped
with protective earthing.
• Handle the product with care during installation, taking care to avoid crush-
ing, denting or dropping it, or contact with liquids of any kind. Keep the
product away from sources of heat and naked flames. Failure to observe the
above can damage the product, and increase the risk of danger or malfunc-
tion. Should this occur, suspend installation work immediately and contact
the Nice Support Service.
• Do not modify any part of the product. Prohibited modifications can only
lead to malfunctions. The manufacturer declines all responsibility for damage
re sulting from unauthorized changes made to the product.
• If the gate or door being automated has a pedestrian gate, then the system
must include a control device that will inhibit the operation of the motor when
the pedestrian gate is open.
• The product's packaging material must be disposed of in full compliance with
local regulations.
1.3 - Warnings for use
• The product is not intended for use by persons, including children, with lim-
ited physical, sensory or mental capacities, or who lack experience or knowl-
edge, unless supervised or trained in the use of the product by a person
responsible for their safety.
• Any children near the automation system must be kept under supervision to
ensure that they do not play with it.
• Do not allow children to play with the fixed control devices. Keep remote
control devices out of the reach of children.
2
PRODUCT DESCRIPTION AND
INTENDED USE
The devices comprising this product are designed to automate a gate or door
with one or two leaves. IMPORTANT! - Any other use apart from that
described herein, including in different environmental conditions from
those described in this manual is to be considered improper use and is
not permitted!
The principal component of the automation system comprises one or two elec-
tric gearmotors (according to the number of leaves to be automated), each
equipped with a direct current motor and epicyclic reduction gear. One of the
gearmotors (mod. HK7024 - HK7024HS) has a control unit that controls its
operation. The Control unit consists of a board with a radio receiver for receiv-
ing the commands sent by the transmitter.
The control unit is designed for connection to several devices belonging to the
Opera system, the Bluebus system and the Solemyo solar powered system,
see chapter 8 - Further information
If it is mains powered, it can house a back-up battery (mod. PS124, optional
accessory) which in the event of a power cut (electricity black-out) guarantees
that the automated device will perform certain manoeuvres in the hours that fol-
low.
In the event of a power cut, the gate leaves can be moved by releasing the
gearmotor with the dedicated key; to perform the manoeuvre manually please
see chapter 3.6.
Other available accessories include the receivers designed with "SM" connec-
tors (SMXI, OXI, etc.), see chapter 8 - Further information.