Maintenance
REPLACING CASSETTE FILTER
Cassette filters should be cleaned regularly either by hand or in
the dishwasher, using a warm and mild dish-washing detergent
solution. Replace filters that are damaged with punctures,
bends, or broken frames. When filters require replacement, use
only genuine replacement filters.
Charcoal filters should only be used in indoor vented
installations and should be replaced periodically (approximately
every 3 to 6 months), depending on frequency of use . Do not
attempt to clean charcoal filters.
REPLACING LIGHT BULBS
When light bulbs burn out, replace them with a 5W GU10 base
light bulb .
- Turn off the range hood, disconnect it from its power
source, and ensure that the lights are cool .
- Turn the bulb (1) in the direction indicated and pull it out
to remove it .
- Push in the new bulb (2) in the direction indicated until
it locks into the socket . Do not release the bulb until
you are sure the bulb has been securely installed . Then
reconnect the power .
- If new bulbs do not operate, ensure that they are
inserted correctly .
QR254S
DANGER:
Turn off the power circuit breaker or the power
switch on the junction box before performing maintenance .
Touching circuitry inside the range hood while it is energized
will result in death or serious injury .
WARNING:
Failure to replace worn out or damaged filters
will increase the risk of fire.
WARNING:
Light bulbs can become hot when turned on .
Do not touch bulbs until they are switched off and cooled .
Touching hot bulbs could cause serious burns .
18
1
2