Electrical Connection; Wiring Diagram - Cola BEAUTY Serie Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

2.7 Electrical connection

Connect one end of the power cable to the rear socket of the stove, and the other to the wall socket.
The voltage supplied by the system must match that specified on the stove dataplate and in the technical data
section of this manual.
During stove idle periods it is advisable to remove the power cable.
- Make sure the electrical system is equipped with an earth and differential switch in accordance
with the
current Regulations.
- The power cable must never touch the stove exhaust pipe.

2.8 Wiring diagram

AIR FLOW METER
INPUTS
NTC
probe
room
probe
suppl.
thermostat
fume
probe
AUGER
2.9 Emergency
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using suitable fire-extinguishers.
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
PLC additional
accessories and console
IGNITER
EXCHANGER 2
EXCHANGER 1
Fume verifier encoder
EARTH
EXCHANGER 3
SYSTEM
ALF = main safety thermostat
ALC = low pressure gauge
FUME EXTRACTION
FAN
49