14 - QUICK CONFIGURATION

This paragraph concerns a quick procedure to set the control unit
and set it at work immediately.
We recommend following these instructions, in order to
check quickly the correct operation of control unit, motor
and accessories, and then changing the configuration in
case of any non-satisfactory parameter.
1. Call up the default configuration: see chapter 13
2. Set items
dir - StoP - Foto - CoS
For the position of the item menus inside the main menu and
for the options related to each item menu, refer to the
chapter 17.
3. Start the self-learning cycle (chapter 15)
4. Check that the automation work properly and if necessary
modify the configuration of the desired parameters.

15 - AUTO-LEARNING END-STOP

This menu allows automatically learning the end-stop positions of
the barrier in opening and closing.
m
ATTENTION: before proceeding, make sure to position
the mechanical stops correctly.
m
ATTENTION: before proceeding set the
m
CAUTION: to perform the self-learning procedure
it is necessary to disable the ADI interface by means of
i.Adi
the menu
(disabled by default). If some safeties are
controlled by means of the ADI module, they will not be
active during the self-learning.
StoP
1. Set the parameter
installed on the barrier (chapter 17).
St.rt
2. Set up the
parameter in
3. Maintain hold pressed push-button OK until the display reads
-SEt
4. Release push-button OK: the display reads
push-button OK only if desired to exit from this menu)
5. Press the push-button
6. Press the push-button OK in order to start the auto-learning:
6.1 The boom moves in closing until reaching the arrest
point (end of closing)
6.2 The boom opens. Press
desired opening. As alternative let the mechanical arrest
intervene.
6.3 The boom recloses automatically and it memorizes the
length.
During normal operations, the travel height of the boom is always
reported to the point of arrest in closing. Any movements of this
point will cause an equal movement of the end opening point.
-SEt
- 50 -
dir
parameter
Foto
CoS
,
,
, based on the safety
StAn
modality (default)
ESC
(press
i
APPr
: the display reads
h
when the boom reaches the
ESC
APPr