PARAMETER
VALUE
LUCi
t .LUC
FLSh
CiCL
AUS
t iM
biSt
Mon
LP.PA
no
Si
Strt
StAn
no
AP.Ch
PrES
oroL
StoP
no
ProS
invE
Foto
no
APCh
CFCh
Ch
DESCRIPTION
Courtesy lights
This menu allows setting up the operation of the courtesy lights
automatically during the barrier's opening cycle.
Timed functioning (from 0 to 20')
Flashing light function
Turned on for the entire duration of the cycle
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver MR
Timed functioning (from 0 a 20')
Bistable functioning
Monostable functioning
Flashing lamp in pause
Function disabled
The flashing lamp works also during the pause time (barrier opened with
active automatic closing).
Function of input START1 and START2
This menu allows choosing the mode of operation of the input START1
and START2
Standard mode
The Start input commands on the terminal strip are disabled.
The radio command function depending of the mode
Open/Close mode
Dead Man mode
Clock mode
Stop input
The input STOP is disabled
The STOP command set the barrier idle: on the next successive command
START the barrier resumes the motion in the same direction
The STOP command sets the barrier idle: on the next successive START
command makes the barrier resume the motion in the opposite direction
to the previous one
Photocell input
This menu allows programming the behavior in case of participation of the
photocell.
Disabled input (the control unit ignores it)
Input always enabled. The interruption of the photocell during the
opening or closing causes the arrest of the barrier.
At reset the barrier resumes the opening movement.
The interruption when in closed barrier inhibits the opening.
Input enabled in closing and with closed barrier.
The interruption of the photocell during the closing causes the reopening.
Input command enabled only in closing. The interruption of the
photocell during the closing causes the reopening.
ATTENTION: if this option is chosen, it is necessary to disable the
test of photocells
StAn
- 54 -
DEFAULT
MEMO
t.LUC
1 '00
Mon
no
StAn
no
no