Descargar Imprimir esta página

golmar G2+ Nexa Art 7 Lite Guía Rápida página 4

Ocultar thumbs Ver también para G2+ Nexa Art 7 Lite:

Publicidad

Idiomas disponibles

Idiomas disponibles

NEXA ART
7
LITE G2+ VIDEO DOOR ENTRY SYSTEM KIT -
SAFETY PRECAUTIONS
Always disconnect the power supply
-
before making modifications to the device
-
The
installation
and handling of these devices must be carried out by
40 cm away from any other wiring
- The wiring must run at least
- In the power supply unit:
Do not overtighten the screws on the connection block.
w
Install the power supply in a dry and protected place free
w
Avoid locations that are humid, dusty or near heat sources.
w
Do not block ventilation holes of the equipments so that air can circulate freely.
w
To avoid damage, the power supply
has to be
w
To prevent electric shock, do not remove the cover or handle the wiring connected to the
w
terminals.
CHARACTERISTICS
( )
*
- Video door entry system with simplified installation (non-polarised 2 wire bus).
- Up to 4 access panels (DPM-G2+ distributor required for more than one access panel) per installation.
- Up to 2 apartments (KIT N5110 ART7 LITE 1P "1 apartment" & KIT N5220 ART7 LITE 2P "2 apartments")
per installation.
- The max. number of monitors/ audio terminals in the apartment is 4 (master, slave1, slave2 and slave3).
- Up to 8 ART7 LITE monitors / audio terminals in parallel (in-out) without distributors (kit 2 apartments).
- Call confirmation tone.
- Visual indications on the door panel for people with impaired hearing (indicating call process,
communication, door open and channel busy).
-
Audible indications on the door panel for people with impaired vision (indicating call
resident unavailable
, door open, c
is
ommunication is finished
SYSTEM OPERATION
- To make a call, the visitor must press the
call
that the call is being made and
door panel
is in progress' message appears indicating that a call is being made. At this moment, the
apartment's monitors receive the call. If the visitor presses the button for another apartment by
mistake, the call can be cancelled by pressing the button for the correct apartment.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
the image from slave monitors 2 or 3, press one of the buttons (located above the raised dots for
the visually impaired) of the monitor to display the image. If the call is not answered within 45
seconds,
door panel
LED
will turn off and the system will become free.
- To establish communication, press
the button below
Door panel LED
will turn off and the led
- Co
mmunication
will last for 90 seconds or until
the screen is
pressed. When communication ends,
will become free. If vocal synthesis is enabled, a 'Communication is finished' message will
indicate that the call is over.
-
To open door
or
of the door panel
, press the
1
2
screen or press the hidden push button below icon
communication processes: one press will activate the lock release for seconds and
LED
will also turn on for seconds. If vocal synthesis is enabled, a 'Door
3
be indicated on the door panel.
-
Detailed operation of the monitor
, see "TART 7 LITE"
( ) For more information see "TKIT632 ART 7 LITE (cód. 5012 636)" manual.
*
https://doc.golmar.es/search/manual/50122636
VILLAS
.
authorised personnel
.
without
risk of
drip or
water
projections
firmly
fixed.
is
in progress,
and
system is busy, try later
).
button of the apartment; an audible sound indicates
LED
will turn on. If vocal synthesis is enabled, a 'Call
displayed on the screen will blink green. To view
off-the-hook icon
sh wn on
o
the screen.
will
turn on
.
the button below
on-the-hook icon
shown on
door panel
LED
will turn off and the system
push
button below
icon
displayed on the
1
displayed
on the screen
during the call or
2
3
door panel
is
open' message will
Cód. 50122627
manual.
2
2
NEXA ART 7 LITE G2+ VIDEO DOOR ENTRY SYSTEM KIT - VILLAS
DOOR PANEL INSTALLATION
( )
*
Positioning the embedding box:
.
Make a hole in the wall to position the top of the door panel at a height of 1.65m.
.
Hole dimensions NCEV-90CS embedding box, 99(W) x 13 ,5(H) x
:
( )
Description of the EL632 G2+ SE module DIP switch:
*
( )
Description of the visual indications on the door panel.
*
( )
Description of the vocal synthesis / tones mode (audible indications on the door panel).
*
( )
Selecting the vocal synthesis language or tones mode of the EL632 G2+ SE module.
*
( )
Description of the P1 and P2 external button of the EL632 G2+ SE module:
*
( )
Change the call code of the P1 and P2 button of the EL632 G2+ SE module:
*
Audio level jumper description (vocal synthesis and tones mode) EL632 G2+ SE module:
Audio level jumper is located on the left side of the back module.
The jumper for volume control, allows to select between a minimum, maximum
or mute of the vocal synthesis and tones mode from the door panel.
1
2 3
( )
1
Jumper placed between 2 and 3, set to minimum volume the vocal
synthesis and tones from the door panel.
1
2 3
Jumper placed between 1 and 2, set to maximum volume the vocal synthesis and tones
from the door panel.
1
2 3
Jumper removed, set to mute volume the vocal synthesis and tones from the door panel.
( )
Factory default.
1
Description of the door panel LED lights (for low light conditions):
The door panel lighting LEDs will turn on during a call if the door panel
lighting at that moment is low. This enables the user to view the person
who has called from the apartment monitor.
LOCK RELEASE INSTALLATION
( )
*
Lock release installation instructions:
If the lock release is to be fitted to a metal door, use a Ø3.5mm drill bit and
thread the hole made. For wooden doors, use a Ø3mm drill bit.
IMPORTANT: The lock release must be Golmar 12V AC or DC.
AC lock release (TF-104 power supply required), fit the varistor supplied
with the kit directly to the lock release terminals to ensure the device
functions correctly.
( ) For more information see
*
https://doc.golmar.es/search/manual/50122636
EN
1850
1650
1450
2
56,5
( )
With the
*
"TKIT632
ART 7 LITE
(cód. 50122
636 manual
)"
3
(D) mm.
( )
1
1
2 3
1
_
+
C1 NA1
Relé 1
3.5 x 25
DIN-7972
M 4 x 8
DIN-963
.
EN

Publicidad

loading

Este manual también es adecuado para:

50122636