Servo sockets, channels 1, 2, 3 ... 9.
1, 2, 3 ... 9
Alternatively: receiver battery socket.
Receiver battery socket
(can also be connected to servo sockets 1 ... 9.
B/D
Duplicated for extra security: twice the conductor
cross-section, twice the number of contacts.
Socket for PC lead.
Receiver battery socket
B
(can also be connected to servo sockets 1 ... 9).
! When connecting the receiver battery, servos, speed
controllers ... it is essential to insert the connector the
correct way round. With other makes of component
always check the pin assignment (see symbols on the
receiver)!
8.
F
U
, F
IRST
SE
UNCTIONS
8.1 LED Codes
LED code
LED Code 0
LED OFF
LED Code 1
LED ON
1,6 sec
LED Code 2
1,6 sec
LED Code 3
1,6 sec
LED Code 5
8.2 The functions of the SET button
Pressing the SET button on the top of the receiver when
switching on initiates the binding process (
In receive mode, the SET button can be used to trigger two addi-
tional functions. The function selected depends on the length of
the button-press:
1. Save FAIL-SAFE settings
Press the SET button for 0.5 to 1 second (
2. RESET receiver to factory default settings
Press the SET button for longer than ten seconds (
While the SET button is pressed, the LED indicates the length of
the button-press with time markers:
Press SET
< 2
button con-
seconds
stantly for
LED
OFF
Purpose
Save
FAIL-SAFE
settings
! Note:
When the Save process is complete, the LED flashes in confir-
mation (LED code 5
8.1.).
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating Instructions for the
RX-9-DR light M-LINK 2.4 GHz receiver
Description
Battery voltage too low
No reception
Binding procedure in progress
Normal receiving operation
Confirmation signal
8.3).
8.5).
8.6).
2 to 10
> 10
seconds
seconds
ON
OFF
RESET
to default
settings
8.3 Binding
The receiver must be set up to match the transmitter before the
system can work. This process is known as "binding".
! Note:
The signal output to the servo sockets is switched off during the
binding procedure. This means that the servos are "soft", and do
not move, while the motor connected to a modern electronic
speed controller remains OFF due to the lack of a signal. Never-
theless, it is important to secure the model and keep well clear
of the power system.
The binding process is necessary in the following cases:
The first time the receiver is used (
After a receiver RESET (
After the transmitter setting for "Fast Response" has been
changed. For more information on this please refer to the
operating instructions supplied with your M-LINK transmitter
or M-LINK RF module.
After the transmitter setting for the frequency range has been
changed. For more information on this please refer to the
operating instructions supplied with your M-LINK transmitter
or M-LINK RF module ("France mode").
If the receiver is to be operated in conjunction with a different
M-LINK transmitter.
8.3.1 Sequence of the binding procedure
1. The first step is always to set the transmitter and receiver to
Binding mode:
Place the transmitter and the receiver aerials close to-
gether.
Switch the transmitter ON in binding mode.
(see the operating instructions supplied with your M-LINK
transmitter or M-LINK RF module).
Switch the RX-9-DR light M-LINK receiver ON in binding
mode:
Use a pointed object to press and hold the SET button
on the top of the receiver (
Switch the receiver ON, or connect the battery:
⇒ The binding procedure runs, the receiver LED
flashes at high frequency
(LED code 2
Now release the SET button.
! Note: the binding process starts automatically when
the receiver is used for the first time, and after a RESET -
even if you have not pressed the SET button.
2. Once the transmitter and receiver are bound to each other,
both switch automatically to normal operation (
⇒ The LED on the receiver flashes slowly
(LED code 3
8.1).
! Note: in most cases the binding process only takes a few
seconds.
8.3.2 Binding: locating and correcting faults
Fault:
During the binding process the receiver LED continues to flash
at a high rate after several seconds.
Cause:
No M-LINK signal of adequate strength detected.
Remedy:
Reduce the distance between your transmitter and the
receiver aerials.
Ensure that your transmitter is switched ON in binding mode.
Repeat the binding procedure.
8.3.1).
8.6).
8.2).
8.1).
8.4):