DeWalt D55168 Manual De Instrucciones página 18

Ocultar thumbs Ver también para D55168:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CODE
POSSIBLE CAUSE
16
Extension cord is wrong length or gauge
17
Loose electrical connections
18
Possible defective motor
19
Paint spray on internal motor parts
20
Pressure release valve on pressure switch has not
unloaded head pressure
21
Fuse blown, circuit breaker tripped
22
Worn Belt
23
Restricted air intake filter
POSSIBLE SOLUTION
Check for proper gauge wire and cord length under Extension
Cords.
Check wiring connection inside pressure switch and terminal
box area.
Contact a D
WALT factory service center or a D
E
authorized service center.
Contact a D
WALT factory service center or a D
E
authorized service center. Do not operate the compressor in
the paint spray area. See flammable vapor warning.
Bleed the line by pushing the lever on the pressure switch to
the "O" position; if the valve does not open, replace switch.
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for our particular
branch circuit.
2. Check for proper fuse. You should use a time
delay fuse.
3. Check for low voltage conditions and/or proper
extension cord.
4. Disconnect the other electrical appliances from
circuit or operate the compressor on its own
branch circuit.
Contact a D
WALT factory service center or a D
E
authorized service center.
Clean or replace air intake filter. Do not operate the air
compressor with the filter removed. Refer to the Air Filter
paragraph in the Maintenance section.
18
WALT
E
WALT
E
WALT
E

Publicidad