Ultraviolet Light Operation; Connecting A Computer To The Usb Charger/Hub - Tripp-Lite CSC32USBWHG Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. 32-Port USB Charger/Hub

5.3 Connecting a Computer to the USB Charger/Hub

In addition to device charging, the USB Charger/Hub is equipped with a hub function that syncs devices and their respective software applications via a
connected computer. To enable the hub function, use the included USB cable to connect the USB-B connector to the unit's Computer Sync Port and
the USB-A connector to a computer's USB port.
Note: When a computer connection is established and multiple devices are connected to the USB Charger/Hub, the charge rate will reduce during syncing and resume to
the normal charge rate upon completion.
Note: The Firmware Upgrade Port requires a mini-USB connection (cable not included).
6. UV Light Operation
Overview
This product is designed to help disinfect the surfaces of hand-held devices, such as tablets and other shareable systems. Bacteria and viruses trans-
mitted via the hands of multiple individuals sharing the stored devices will be reduced. The result is an improved level of shared-system hygiene. The
ultraviolet lamps within this unit emit UV light at a frequency proven effective in arresting microorganisms such as viruses, bacteria, yeast and molds.
This process either destroys the microorganism or neutralizes its ability to reproduce. The unit features a 10-minute sanitizing cycle.
Usage
Once the user opens and closes the doors on the unit, the internal timer
resets. The timer cycles for 10 minutes when the "START" button is
pressed.
1. Open the door of the CSC32USBWHG Charging Station.
2. Insert devices and ensure the unit is plugged in.
3. Close the door. The "DOOR CLOSED / READY" LED will illuminate. Press
the "START" button and the UV lights will turn on automatically.
4. If the door is opened before the timer finishes its 10-minute cycle, the
lights will turn off and the timer will be reset for the next sanitizing
cycle.
Note: Both charging station doors must be closed before the start button is pressed.
The UV lights will not turn on if either door is open. This helps ensure non-protected
eyes or skin are never exposed directly to UV light.
Maintenance and Troubleshooting
• Check that the lamp connector is securely attached to lamp.
• Check that the fuse is in good working order. Replace if necessary.
• Check that proper power is being supplied to the device and that the switch lights when turned on.
• Lamps should be cleaned every six months to remove any dust accumulation on the bulbs that might reduce the effectiveness of the UVC light.
• Check if switch is working properly by opening and closing the cabinet doors and see the light turning off/on. The timer should operate for
10 minutes before shutting off.
Warnings and Safety
• A broken UV lamp is extremely unlikely to have any negative impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove
the parts while wearing gloves. Put the parts in a sealed plastic bag and take it to your local waste facility for recycling. Do not use a vacuum
cleaner.
• CAUTION! The lamps are a Risk Group 3 Ultra Violet product. These lamps emit high-power UV radiation that can cause severe injury to the skin
and eyes. Avoid skin and eye exposure to unshielded product. Use only in an enclosed environment that shields users from radiation.
Dimensional Drawing
UV LIGHT
CYCLE "ON"
(10 min)
Product
A (max.)
TUV 8W
288.3 mm
FAM/10X25BOX
6
DOOR CLOSED
DOOR CLOSED
/ "READY"
/ "READY"
START BUTTON
B (max.)
B (min.)
C (max.)
295.4 mm
293 mm
302.5 mm
D (max.)
16 mm

Publicidad

Tabla de contenido
loading

Tabla de contenido