41006
• Start-up after configuration: A, B, C (optional), D2. The device waits to be put into operating status (to be done with the
configuration software): on receiving the command, it goes into D3 status without restarting.
• Start-up in operating status: A, B, C (optional), D3.
Firmware Updating
Status
On
Updating – STEP 1
Updating – STEP 2
Updating – STEP 3
Times: 0.25 s ON, 0.25 s OFF.
3
The firmware updating procedure of the electronic audio video module is performed in three steps, each of which is identified
by a specific aspect of the LEDs as indicated above. After updating, the device restarts automatically.
Installation rules
Installation should be carried out by qualified personnel in compliance with the current regulations regarding the installation of
electrical equipment in the country where the products are installed.
Conformity
EMC directive
Standards EN 60065, EN 61000-6-1 and EN 61000-6-3.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included
with other general waste at the end of its working life. The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one. Products for disposal can be consigned free of charge (without
any new purchase obligation) to retailers with a sales area of at least 400m
sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid
the potential negative effects on the environment and people's health, and encourages the re-use and/or recycling of the
construction materials.
LED L3
LED L2
ON
OFF
OFF
Blinking
Blinking
Blinking
3
, if they measure less than 25cm. An efficient
2
EN
LED L1
ON
ON
OFF
Blinking
3
Blinking
Blinking
3
3
3
3
17